CFS1
CFS1 solvent-borne stain binder (for spray application)
Solvent-borne (ОР) stain binder intended for SPRAY application (0–200 % on the dye). It goes into the dye concentrate before thinning: evens out colour, gives the stain the rheology suited to the application method and improves adhesion of the next coat. For roller application the range has CFS3, for wiping CFS4 (200–400 %); water-borne equivalents are CFH1 (spray), CFH2 (dipping), CFH3 (roller), CFH6 (wiping); for CIT «Kromoroller» there are also CIC11/CIC12.
- Spray-staining veneer and solid wood with solvent CTU, CLT, CPS, CIT dyes
- CPS9/CPS10 pigment stains — their cards list CFS1 (0–400 %); for wiping/pore highlighting the catalog points to CFS4, for roller to CFS3
- Staining mouldings/frames on a UV line ahead of VTS40041 UV sealer
- Staining raised-panel doors ahead of PTS20 PU primer
Ask about CFS1
Answers are based on the CFS1 data and the products it mixes with.
Mixing matrix
- CTU1 / CTU2 / CTU3 / CTU8 / CTU9 / CTU21 / CTU22 / CTU23 / CTU24 / CTU25 / CTU26 / CTU27 / CTU28 / CTU29 / CTU30dye_partner% by weight: 0–200 % of dyeofficial% by volume: 0–200 % of dyeofficial
CTU universal transparent dyes (every colour). The card lists the binder as «CFS1 / CFH1»: CFS1 for solvent-thinned stain, CFH1 for water-thinned.
The 2022 catalog gives CTU with CFS1 only, 0–200 %. CTU over a primer coat must be solvent-thinned (official card).
- % by weight: 0–200 % of dyeofficial% by volume: 0–200 % of dyeofficial
CLT1–CLT9 «Kromolux» dyes thinned with solvent (binder «CFS1/CFH1»).
Per the Milesi TDS the CLT series is a «stain without binder»; CFS1 goes in when you want more even colour and the dye locked down. CLT11, CLT12 and CLT18 cards name no binder.
- CLT10dye_partner% by weight: 0–200 % of dyeofficial% by volume: 0–200 % of dyeofficial
White CLT10 — CFS1 only (it can't be water-thinned, so CFH1 is out).
Milesi CLT TDS: «CLT10 can't be diluted with water».
- % by weight: 0–400 % of dyeofficial% by volume: 0–400 % of dyeofficial
CPS9 (black) and CPS10 (white) solvent pigment concentrates: their cards list CFS1 as the only binder, 0–400 %. The catalog clarifies that CFS1 is the spray binder; for wiping to pick out pores use CFS4, for roller CFS3.
2022 catalog: CPS binder «CFS1, CFS3, CFS4 — 0–400 %». Binder table (catalog): CFS1 spray 0–200 %, CFS3 roller 200–400 %, CFS4 wiping 200–400 %. 2025-26 catalog: «with the special binder it can be wiped on» — that is CFS4, not CFS1.
- % by weight: 0–40 % of dyeofficial% by volume: 0–40 % of dyeofficial
CIT «Kromoroller» dyes (binder «CIC11/CIC12/CFS1», 0–40 %). CIT8's card doesn't list CFS1 (CIC11/CIC12/LZC97).
For wiping CIT has its own binder CIC12 (20–30 % into the ready stain, per the dealer).
- % by weight: 150 % of dyeschedule
Mouldings & frames (UV line): stain after brush sanding K60/K80, 80 g/m², dry 5 min at 25–30 °C, then VTS40041 UV sealer.
- % by weight: 200 % of dyeschedule
Raised-panel doors (PU): stain after P150–P220 flats / K60–K80 profiles, 80–100 g/m², dry 5 min at 20–25 °C, then PTS20 : C25 : S50 = 100 : 50 : 20.
| Role | Material | % by weight | % by volume | When |
|---|---|---|---|---|
| dye_partner | CTU1 / CTU2 / CTU3 / CTU8 / CTU9 / CTU21 / CTU22 / CTU23 / CTU24 / CTU25 / CTU26 / CTU27 / CTU28 / CTU29 / CTU30 | 0–200 % of dyeofficial | 0–200 % of dyeofficial | CTU universal transparent dyes (every colour). The card lists the binder as «CFS1 / CFH1»: CFS1 for solvent-thinned stain, CFH1 for water-thinned.The 2022 catalog gives CTU with CFS1 only, 0–200 %. CTU over a primer coat must be solvent-thinned (official card). |
| dye_partner | CLT1 / CLT2 / CLT3 / CLT4 / CLT5 / CLT6 / CLT7 / CLT8 / CLT9 | 0–200 % of dyeofficial | 0–200 % of dyeofficial | CLT1–CLT9 «Kromolux» dyes thinned with solvent (binder «CFS1/CFH1»).Per the Milesi TDS the CLT series is a «stain without binder»; CFS1 goes in when you want more even colour and the dye locked down. CLT11, CLT12 and CLT18 cards name no binder. |
| dye_partner | CLT10 | 0–200 % of dyeofficial | 0–200 % of dyeofficial | White CLT10 — CFS1 only (it can't be water-thinned, so CFH1 is out).Milesi CLT TDS: «CLT10 can't be diluted with water». |
| dye_partner | CPS9 / CPS10 | 0–400 % of dyeofficial | 0–400 % of dyeofficial | CPS9 (black) and CPS10 (white) solvent pigment concentrates: their cards list CFS1 as the only binder, 0–400 %. The catalog clarifies that CFS1 is the spray binder; for wiping to pick out pores use CFS4, for roller CFS3.2022 catalog: CPS binder «CFS1, CFS3, CFS4 — 0–400 %». Binder table (catalog): CFS1 spray 0–200 %, CFS3 roller 200–400 %, CFS4 wiping 200–400 %. 2025-26 catalog: «with the special binder it can be wiped on» — that is CFS4, not CFS1. |
| dye_partner | CIT1 / CIT2 / CIT3 / CIT9 / CIT9280 | 0–40 % of dyeofficial | 0–40 % of dyeofficial | CIT «Kromoroller» dyes (binder «CIC11/CIC12/CFS1», 0–40 %). CIT8's card doesn't list CFS1 (CIC11/CIC12/LZC97).For wiping CIT has its own binder CIC12 (20–30 % into the ready stain, per the dealer). |
| schedule | CTU / S12 | 150 % of dyeschedule | — | Mouldings & frames (UV line): stain after brush sanding K60/K80, 80 g/m², dry 5 min at 25–30 °C, then VTS40041 UV sealer. |
| schedule | CTU / S12 | 200 % of dyeschedule | — | Raised-panel doors (PU): stain after P150–P220 flats / K60–K80 profiles, 80–100 g/m², dry 5 min at 20–25 °C, then PTS20 : C25 : S50 = 100 : 50 : 20. |
Percentages are per 100 parts of component A.
Characteristics
- Function
- Связующее для красителей на растворителе, способ нанесения — распыление, 0–200 %. Улучшает равномерность цвета, задаёт реологию под метод нанесения, улучшает адгезию следующего слоя ЛКМ.catalog
- Compatibility
- Растворители S10, S12, S90, LZC97; не для разведения водойrecommended
- Drying · Flash-off (min)
- 5 min, stain+binder layer before primingschedule
- Drying · Conditions
- 20–25 °C (PU doors); 25–30 °C on UV line
- Application method
- spraycatalog
- Dose (catalogue)
- 0–200 % on the dyecatalog
Application
HVLP
- Nozzle
- 1–1.3 mmrecommended
- Pressure · air
- 1.5–2 bar at gun inlet (cap ≤0.7)recommended
- Spray viscosity
- 10–12 s DIN4 (as thinned stain)recommended
- Consumption
- 80–100 g/m² (stain + binder + thinner)official
- Coats
- 1 (2nd light coat to even up colour)recommended
- Flash-off
- 5 min at 20–25 °C (25–30 °C on UV line)schedule
Lay it down as an even, slightly dry mist with no runs; go light on end grain. Prime right after the 5-minute flash.
Conventional spray
- Nozzle
- 1.2–1.4 mmrecommended
- Pressure · air
- 2–3 barrecommended
- Consumption
- 80–100 g/m²official
Airmix (air-assisted airless)
- Nozzle
- 0.18–0.23 mm (07–09 thou), 20–40° fanrecommended
- Pressure · fluid
- 8–20 barrecommended
- Pressure · air
- 1–2 barofficial
- Consumption
- 80–100 g/m²official
Cloth or pad
- Consumption
- 80–100 g/m² (spray, then wipe)official
- Why this binder
- CFS4 — РАСТИРАНИЕ 200-400 % (CFS1 — РАСПЫЛЕНИЕ 0-200 %)catalog
«Spray then wipe» is listed on the CPS/CIT cards. For wiping the catalog provides a separate binder, CFS4 (200–400 %); CFS1 is the spray binder. Wipe off along the grain and leave the pigment in the pores.
Roller
- Consumption
- 10–20 g/m² (CPS); 5–15 g/m² for CITofficial
Roller-coater application on a line (CPS 10–20 g/m², CIT 5–15 g/m²). For roller the catalog lists binder CFS3 (200–400 %), not CFS1.
Process and compatibility
- Substrate preparation
- Flats P150–P180–P220, profiles K60/K80 pads (doors); mouldings K60/K80 brushes. Remove all dust.schedule
- Goes over
- bare sanded wood/veneer
- Goes under
- [object Object] / [object Object] / [object Object]
- Sanding
- Don't sand the stain coat itself — sand the first primer coat (P240–P320 / K120).schedule
- Temperature and humidity
- 20–30 °C for staining/drying per schedulesschedule
- Don'ts
- Don't thin a CFS1 mix with water — use CFH1 for water-borne stain
- Don't exceed 200 % on CTU/CLT, 400 % on CPS pigment stains (40 % on CIT)
- CFS1 isn't the first choice for roller or wiping — the catalog gives CFS3 (roller) and CFS4 (wiping)
- No need to leave the stain overnight — schedules prime after a 5-minute flash
Storage
Safety: Solvent-borne: flammable, vapours harmful. Spray in a booth with extraction and an A-filter respirator; keep away from ignition sources. (General solvent-coating rules — no SDS for CFS1 found.)
Used in finishing systems
Mixed into
CIT1 / CIT2 / CIT23 / CIT3 / CIT9 / CIT9280 / CLT1 / CLT10 / CLT11 / CLT12 / CLT14 / CLT15 / CLT16 / CLT17 / CLT18 / CLT2 / CLT20 / CLT21 / CLT22 / CLT23 / CLT24 / CLT3 / CLT4 / CLT41 / CLT42 / CLT43 / CLT44 / CLT45 / CLT46 / CLT47 / CLT48 / CLT49 / CLT5 / CLT50 / CLT51 / CLT52 / CLT53 / CLT54 / CLT55 / CLT56 / CLT57 / CLT58 / CLT59 / CLT6 / CLT60 / CLT61 / CLT62 / CLT63 / CLT64 / CLT7 / CLT8 / CLT9 / CPS / CPS010 / CPS011 / CPS017 / CPS021 / CPS030 / CPS033 / CPS036 / CPS037 / CPS040 / CPS043 / CPS044 / CPS045 / CPS046 / CPS1 / CPS10 / CPS2 / CPS22 / CPS23 / CPS24 / CPS25 / CPS3 / CPS51 / CPS52 / CPS53 / CPS54 / CPS55 / CPS56 / CPS57 / CPS60 / CPS61 / CPS8 / CPS9 / CTU / S12
Sources
Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).
- CTU card: Связующее CFS1/CFH1 0–200 % вес/объём; thinner S10/S12/S90/вода 500–1000 %; 80–100 g/m² spray (same on all 15 CTU cards)
- CLT1–CLT9 cards: CFS1/CFH1 0–200 %; thinner S10/S12/S90/LZC97/вода 500–1000 %
- CLT10 card: CFS1 0–200 %
- CIT1/2/3/9/9280 cards: CIC11/CIC12/CFS1 0–40 %; thinner 500–2000 %; spray+wipe 80–100, roller 5–15 g/m²
- CPS9 card: CFS1 0–400 %; thinner S10/S12/S90 500–2000 %; spray+wipe/spray 80–100, roller 10–20 g/m²
- CPS10 card: CFS1 0–400 %
- Schedule: CTU 100 : CFS1 150 : S12 500, 80 g/m², 25–30 °C 5 min → VTS40041
- Schedule: CTU 100 : CFS1 200 : S12 500, 80–100 g/m², 20–25 °C 5 min → PTS20/C25/S50
- Sibling binder CIC12 (Milesi): 20–30 % into ready CIT stain, viscosity A 53±3, full dry 3–4 h — context only, NOT applied to CFS1
- Sibling water binder CFH2 «ВР для окунания»: solids 41±1 %; recipe CFH2 40 % / water 60 % / CTH 1–10 % — context only
- Dealer search: no CFS1 result; direct URL /cfs1/ 404
- Older official Technocolor catalog p.12 «Связующее для красителей»: CFS1 распыление 0–200, CFS3 вальцы 200–400, CFS4 растирание 200–400, CFH1/2/3/6; binder functions (colour uniformity, rheology, adhesion)
Not covered by the sources
- solids_pct (not published anywhere; dealer has no CFS1 card)
- viscosity of CFS1 as supplied
- density
- resin type (nitro/acrylic/alkyd — unknown)
- pot life / shelf life of a stain+CFS1 mix
- storage: shelf life, temperature, packaging sizes
- SDS / hazard classes
- no Technocolor or Milesi TDS found for CFS1 (web-search budget exhausted; dealer and 3 other dealer searches empty)
- current availability: CFS1 may be discontinued — dealer link 404
- CFS3/CFS4 (catalogs only) — whether still produced; no official/dealer pages