CLT7
CLT7 Kromolux wood dye, classic walnut
Concentrated transparent wood dye (stain) from the Kromolux range by MILESI, no binder, classic-walnut shade. Very even colour and high clarity; the high strength gives deep dark tones while the grain still shows through. Reduce 500–1000 % with solvent thinner (S10/S12/S90/LZC97) or deionised water, with or without CFS1/CFH1 binder (up to 200 %). Intermixes with the other dyes of the series in any ratio. Can be topcoated with polyester, polyurethane and nitrocellulose lacquers.
- Staining any timber — veneer and solid
- Furniture, mouldings, frames, general joinery — spray
- Walnut tone on pale timber (beech, birch, alder, pine, oak)
- Shade matching mixed with the other CLT dyes
Mix calculator
Ask about CLT7
Answers are based on the CLT7 data and the products it mixes with.
Mixing matrix
- % by weight: 500–1000 %official% by volume: 500–1000 %official
Always — CLT7 is supplied as a concentrate. 500 % for a deep, dark walnut; 1000 % for a light tint.
Official line: 'S10/S12/S90/LZC97/water 500–1000 %'. The dealer gives the same range for S10/S12/S90/water and does not mention LZC97.
- S10Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Fast, strong thinner — for staining close-grained timber (beech, birch, maple, alder, cherry), small parts, a cool shop.
Thinner roles per the thinner table in the Technocolor 2025–2026 catalog.
- S12Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Medium evaporation — for medium-pore timber (walnut, mahogany); the all-round choice for hand spraying. Technocolor's stain schedules use S12.
Thinner roles per the thinner table in the Technocolor 2025–2026 catalog.
- S90Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Slow — for open-pore timber (oak, ash, anegre), big panels, shop above ~25 °C: gives the dye time to soak into the pores, fewer stripes and lap marks.
Thinner roles per the thinner table in the Technocolor 2025–2026 catalog.
- WATERThinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Water-borne stain: less smell/VOC, pops the figure more, but raises the grain and dries slowly (8 h before sealer per the TDS).
Deionised water only — tap water makes the dye flocculate and hurts colour stability (dealer note). With water use only the water-borne binder CFH1 (CFS1 is the solvent binder).
- LZC97Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
As a co-solvent alongside the main thinner or water — in the CLT TDS LZC97 is a small share of the blend (0.5–1 part per part of dye), not used alone. The Milesi LZC-series TDS describes LZC97 as a slow thinner for roller stains (CIT series).
No LZC97 page on t-color.ru or at the dealer. Description from the Milesi LZC-series TDS (SG 0.918, slow).
- % by weight: 1 : 0.5 : 9.5 (CLT : LZC97 : LZC1000) — 1000 % totaldatasheet
Manufacturer's (Milesi) suggested solvent dilution.
LZC1000 is not in the Technocolor range. Per the Milesi LZC TDS it is a fast acetone-based thinner (SG 0.790) for gun cleaning, spray stains and polyester; nearest Technocolor equivalent by purpose is S10 (fast, for stains).
- LZC97 / WATERThinner% by weight: 1 : 1 : 14 (CLT : LZC97 : water) — 1500 % totaldatasheet
Manufacturer's suggested water dilution.
Deionised water. 1500 % is beyond Technocolor's official 1000 % ceiling — expect a lighter tone.
- CFS1Additive% by weight: 0–200 %official% by volume: 0–200 %official
Solvent-borne spray binder — with S10/S12/S90: the sealer doesn't drag the dye, more even colour on end grain, less grain raising.
0 % is allowed. CFS1 is the 'Связующее ОР для распыления' (solvent-borne spray binder) — stated outright on the dealer's CPS10 page, which lists CFS1 alone. On the CLT7 page the dealer lists codes 'CFH1 / CFS1' against labels 'solvent / water' in swapped order — don't be misled.
- CFH1Additive% by weight: 0–200 %official% by volume: 0–200 %official
Water-borne spray binder — when CLT7 is reduced with deionised water.
Don't put CFH1 into a solvent-reduced batch. CFH1 is the 'Связующее ВР для распыления' (water-borne spray binder): the water-only CPH dyes (e.g. CPH9) list CFH1 only, and the dealer labels CFS1 as the solvent binder.
- % by weight: CTU 100 : CFS1 200 : S12 500 %schedule
'Panel doors, PU' schedule — dye + binder under a PU system, 80–100 g/m², 5 min at 20–25 °C.
The schedule names CTU, not CLT; CLT7 is the same class (transparent concentrate, same S10/S12/S90 at 500–1000 %, CFS1 0–200 %, 80–100 g/m²), and the recipe sits inside CLT7's official ranges.
- % by weight: CTU 100 : CFS1 150 : S12 500 %schedule
'Mouldings and frames, UV' schedule — 80 g/m², 5 min at 25–30 °C before the UV sealer.
Analogue: the schedule uses CTU, not CLT (see above).
| Role | Material | % by weight | % by volume | When |
|---|---|---|---|---|
| Thinner | S10 / S12 / S90 / LZC97 / WATER | 500–1000 %official | 500–1000 %official | Always — CLT7 is supplied as a concentrate. 500 % for a deep, dark walnut; 1000 % for a light tint.Official line: 'S10/S12/S90/LZC97/water 500–1000 %'. The dealer gives the same range for S10/S12/S90/water and does not mention LZC97. |
| Thinner | S10 | 500–1000 %official | 500–1000 %official | Fast, strong thinner — for staining close-grained timber (beech, birch, maple, alder, cherry), small parts, a cool shop.Thinner roles per the thinner table in the Technocolor 2025–2026 catalog. |
| Thinner | S12 | 500–1000 %official | 500–1000 %official | Medium evaporation — for medium-pore timber (walnut, mahogany); the all-round choice for hand spraying. Technocolor's stain schedules use S12.Thinner roles per the thinner table in the Technocolor 2025–2026 catalog. |
| Thinner | S90 | 500–1000 %official | 500–1000 %official | Slow — for open-pore timber (oak, ash, anegre), big panels, shop above ~25 °C: gives the dye time to soak into the pores, fewer stripes and lap marks.Thinner roles per the thinner table in the Technocolor 2025–2026 catalog. |
| Thinner | WATER | 500–1000 %official | 500–1000 %official | Water-borne stain: less smell/VOC, pops the figure more, but raises the grain and dries slowly (8 h before sealer per the TDS).Deionised water only — tap water makes the dye flocculate and hurts colour stability (dealer note). With water use only the water-borne binder CFH1 (CFS1 is the solvent binder). |
| Thinner | LZC97 | 500–1000 %official | 500–1000 %official | As a co-solvent alongside the main thinner or water — in the CLT TDS LZC97 is a small share of the blend (0.5–1 part per part of dye), not used alone. The Milesi LZC-series TDS describes LZC97 as a slow thinner for roller stains (CIT series).No LZC97 page on t-color.ru or at the dealer. Description from the Milesi LZC-series TDS (SG 0.918, slow). |
| Thinner | LZC97 / LZC1000 | 1 : 0.5 : 9.5 (CLT : LZC97 : LZC1000) — 1000 % totaldatasheet | — | Manufacturer's (Milesi) suggested solvent dilution.LZC1000 is not in the Technocolor range. Per the Milesi LZC TDS it is a fast acetone-based thinner (SG 0.790) for gun cleaning, spray stains and polyester; nearest Technocolor equivalent by purpose is S10 (fast, for stains). |
| Thinner | LZC97 / WATER | 1 : 1 : 14 (CLT : LZC97 : water) — 1500 % totaldatasheet | — | Manufacturer's suggested water dilution.Deionised water. 1500 % is beyond Technocolor's official 1000 % ceiling — expect a lighter tone. |
| Additive | CFS1 | 0–200 %official | 0–200 %official | Solvent-borne spray binder — with S10/S12/S90: the sealer doesn't drag the dye, more even colour on end grain, less grain raising.0 % is allowed. CFS1 is the 'Связующее ОР для распыления' (solvent-borne spray binder) — stated outright on the dealer's CPS10 page, which lists CFS1 alone. On the CLT7 page the dealer lists codes 'CFH1 / CFS1' against labels 'solvent / water' in swapped order — don't be misled. |
| Additive | CFH1 | 0–200 %official | 0–200 %official | Water-borne spray binder — when CLT7 is reduced with deionised water.Don't put CFH1 into a solvent-reduced batch. CFH1 is the 'Связующее ВР для распыления' (water-borne spray binder): the water-only CPH dyes (e.g. CPH9) list CFH1 only, and the dealer labels CFS1 as the solvent binder. |
| Additive | CFS1 / S12 | CTU 100 : CFS1 200 : S12 500 %schedule | — | 'Panel doors, PU' schedule — dye + binder under a PU system, 80–100 g/m², 5 min at 20–25 °C.The schedule names CTU, not CLT; CLT7 is the same class (transparent concentrate, same S10/S12/S90 at 500–1000 %, CFS1 0–200 %, 80–100 g/m²), and the recipe sits inside CLT7's official ranges. |
| Additive | CFS1 / S12 | CTU 100 : CFS1 150 : S12 500 %schedule | — | 'Mouldings and frames, UV' schedule — 80 g/m², 5 min at 25–30 °C before the UV sealer.Analogue: the schedule uses CTU, not CLT (see above). |
Percentages are per 100 parts of component A.
Characteristics
- Viscosity
- 24 ± 2 sdealer
- Density
- 0.965 ± 0.05 g/cm³ (specific gravity at 20 °C)datasheet
- Concentration
- very high concentrationofficial
- Uniformity
- excellent uniformityofficial
- Drying · Touch-dry
- 30 s (LZC1000 solvent); 8 h (water)datasheet
- Drying · Overcoat with sealer
- after 1 min (solvent-reduced); after 8 h (water-reduced)datasheet
- Drying · IR drying 60 °C
- 10 min (solvent); 20 min (water)datasheet
- Drying · Conditions
- 20 °C, 70 % RH (TDS test conditions)
- Overcoatable with
- PE,PU,NCdatasheet
- Characteristics page
- vocabulary per the official characteristics pageofficial
Colours
- CLT7 · classic walnut
Application
HVLP
- Consumption
- 80–100 g/m²official
- Nozzle
- 1–1.3 mmrecommended
- Pressure · air
- 1.5–2 bar at gun inlet (trigger pulled)recommended
- Pressure · fluid
- 0.3–0.8 bar (pressure pot) or gravity cuprecommended
- Spray viscosity
- 10–13 s DIN4recommended
- Coats
- 1–2 coatsrecommended
- Flash-off
- 5 minschedule
- Recoat
- sealer after 1 min (solvent, LZC1000) / after 8 h (water)datasheet
- Sanding between coats
- Never sand the stain coat.recommended
15–20 cm distance, 50 % overlap, constant speed and distance — a dye shows every stripe. Use S12/S90 on verticals and edges. End grain soaks up colour fast — go lighter there. (Recommendation.)
Conventional spray
- Consumption
- 80–100 g/m²official
- Nozzle
- 1–1.2 mmrecommended
- Pressure · air
- 2–3 bar at gun inletrecommended
- Spray viscosity
- 10–13 s DIN4recommended
Hand spray; TDS dilution 500–800 %.
Airmix (air-assisted airless)
- Consumption
- 10–20 g/m²datasheet
- Nozzle
- 0.18–0.23 mmrecommended
- Pressure · fluid
- 4–8 barrecommended
- Pressure · air
- 1–2 barofficial
For automatic guns/reciprocators on a line; hand airmix on dye only with the smallest tip.
Airless
- Consumption
- 10–20 g/m²datasheet
- Nozzle
- 0.18–0.23 mmrecommended
- Pressure · fluid
- 40–70 barrecommended
Fixed automatic guns on a line only; don't hand-spray dye airless — far too much output.
Electrostatic
- Consumption
- 5–20 g/m²datasheet
The TDS row is not electrostatic but an 'automatic rotating spray gun (carousel)', 700–1500 % dilution. Filed here for lack of a separate method; electrostatic application is not claimed anywhere for CLT7.
Process and compatibility
- Substrate preparation
- Flat surfaces belt-sanded P150 → P180 → P220, profiles with abrasive mats K60/K80 ('Panel doors, PU' schedule), de-dust. Coarser grit = more uptake, darker tone. For water-reduced stain, wet the wood first, dry and fine-sand the raised grain.schedule
- Goes over
- bare wood (sanded)
- Goes under
- polyester sealers/lacquers / PU sealers/lacquers / NC lacquers / UV sealers (per Technocolor UV schedule for the analogous CTU dye)
- Sanding
- Never sand the dye coat — you'll cut through to bare wood. Knock down raised fibres on the first sealer coat: the PU door schedule sands the PTS20 sealer at P240/P280/P320, profiles with K120 mat; go gently on edges.schedule
- Temperature and humidity
- 20 °C, 70 % RH referencedatasheet
Storage
- Shelf life
- 8 months from deliverydatasheet
- Storage temperature
- 18–25 °C, tightly closed, protect from moisture and contaminationdatasheet
- Packaging
- 1 l, 5 l (3 191 ₽/l, on order, checked 2026-10-04)dealer
Sources
Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).
- official page: properties, spray 80–100 g/m², thinners S10/S12/S90/LZC97/water 500–1000 %, binder CFS1/CFH1 0–200 %
- dealer page: MILESI, properties + intermixability, 80–100 g/m², mix table, viscosity 24±2 at 20 °C, deionised-water note, 1 l / 5 l, 3 191 ₽/l
- dealer search for CLT7
- Milesi/IVM CLT 'Kromolux' TDS (Oct 2006, rev. I): CLT7 density 0.965, viscosity 24″ ISO 3, dilutions per method, drying, overcoat, shelf life, storage, series colours
- official application-methods page (airmix air 1–2 bar)
- official characteristics vocabulary
- schedule PU panel doors: CTU 100 : CFS1 200 : S12 500, 80–100 g/m², 5 min 20–25 °C (analogue)
- schedule UV mouldings: CTU 100 : CFS1 150 : S12 500, 80 g/m², 5 min 25–30 °C (analogue)
- water-only CPH dye lists CFH1 only — basis for CFH1 = water binder
- dealer CPS10 page: 'CFS1 — Связующее ОР для распыления' (confirms CFS1 = solvent binder)
Not covered by the sources
- Solids content — not published (TDS field blank, dealer silent)
- Dealer viscosity cup not stated (TDS: ISO 3 mm, 24 ± 2 s)
- Lightfastness rating, chemical resistance — not published
- No SDS / hazard classification found
- Conflict: spread 80–100 g/m² (Technocolor/dealer) vs 5–20 g/m² manual spray (Milesi TDS, basis not stated)
- TDS is Oct 2006 rev. I — may be superseded
- Drying times are from the Milesi TDS only — no Technocolor-specific drying data
- No official schedule uses CLT7 directly (schedule ratios are CTU analogues)
- CLT7 not in the 2025–2026 catalog transcripts
- Nozzle/pressure, spray viscosity, coats are derived, not Technocolor data
- LZC97 and LZC1000 (TDS solvents) — no Technocolor/dealer pages; described only in the Milesi LZC-series TDS; LZC1000 not sold by Technocolor
- Dealer CLT7 mix table shows binder labels swapped ('CFH1 / CFS1' vs 'ОР / ВР'); CFS1 = solvent binder confirmed on dealer CPS10 page
- Substrate grit split veneer vs solid is not published; schedule gives P150–P220 for flat surfaces only