CLT2
CLT2 Kromolux dye concentrate, orange
Concentrated transparent wood dye (stain). Gives an even, uniform colour and lets you go dark while keeping the wood see-through. Cuts with water or with solvent, and can be used with or without a binder. All dyes in the series intermix in any ratio to hit the target shade.
- Colouring all kinds of wood species (veneer and solid)
- Evening out colour variation, enriching or changing the wood colour
- Base shade for blending with other CLT dyes
Mix calculator
Ratio 100 : 750.0
| Component | Weigh out |
|---|---|
| CLT2part A | 58.8 g |
| S10Thinner | 441 g |
| Total | 500 g |
Covers roughly 5.56 m² at 90 g/m².
Pot life of the mix: not applicable (1K, no hardener) — mixed solvent stain keeps in a closed can; water-cut stain: mix what you use in a shift.
Ask about CLT2
Answers are based on the CLT2 data and the products it mixes with.
Mixing matrix
- S10Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Fast thinner — staining fine-pored woods (e.g. beech, birch, maple, alder).
SG 0.790 ± 0.01; also used to flush equipment (t-color.ru S10 page). 'Fine-pored wood' use from catalogue p.19; species examples are derived. Dealer labels S10 'thinner for polyester'.
- S12Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Medium evaporation — staining medium-pored woods (e.g. cherry, walnut).
Nitro thinner, suitable for cutting dyes (t-color.ru S12 page). Wood-type use from catalogue p.19; species examples are derived. S12 is the thinner used in the official CTU dye schedules.
- S90Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Slow — staining coarse-pored woods (e.g. oak, ash); also big panels or a hot shop: gives the stain time to level out without blotches or lap marks.
Coarse-pored wood and slow evaporation from catalogue p.19 and dealer S90 page; species examples and 'big panels / heat' are derived.
- LZC97Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Listed on the official page; no product description for LZC97 found.
Missing from the dealer's mixing table.
- WATER (deionised)Thinner% by weight: 500–1000 %official% by volume: 500–1000 %official
Water-cut stain: penetrates deeper and pops the grain more; where you want minimal solvent.
Deionised (distilled) water only — tap water makes the dye flocculate and hurts colour stability in the can. Raise the grain with water, dry and denib before a water stain.
- CFS1Additive% by weight: 0–200 %official% by volume: 0–200 %official
Binder for the solvent-cut stain (S10/S12/S90): locks the dye down so the next primer coat drags/bleeds it less.
Solvent/water assignment of CFS1/CFH1 is inferred: the dealer labels them 'solvent / water' in the opposite order to the codes, but the official schedules pair CFS1 with S12 and CFH1 with water, and Technocolor codes use S = solvent, H = water.
- CFH1Additive% by weight: 0–200 %official% by volume: 0–200 %official
Binder for the water-cut stain.
Analogue: 'Raised-panel doors (PU)' schedule — written for CTU, not CLT2; 80–100 g/m², 5 min at 20–25 °C, then PTS20 PU primer.
Analogue: 'Mouldings and frames (UV)' schedule — written for CTU; 80 g/m², 5 min at 25–30 °C, then VTS40041 UV primer.
- CFH1 / WATERAdditive
Analogue: water schedule (CTH) — 400 % CFH1 exceeds the 0–200 % official limit for CLT2; stay at ≤200 % with CLT2.
| Role | Material | % by weight | % by volume | When |
|---|---|---|---|---|
| Thinner | S10 | 500–1000 %official | 500–1000 %official | Fast thinner — staining fine-pored woods (e.g. beech, birch, maple, alder).SG 0.790 ± 0.01; also used to flush equipment (t-color.ru S10 page). 'Fine-pored wood' use from catalogue p.19; species examples are derived. Dealer labels S10 'thinner for polyester'. |
| Thinner | S12 | 500–1000 %official | 500–1000 %official | Medium evaporation — staining medium-pored woods (e.g. cherry, walnut).Nitro thinner, suitable for cutting dyes (t-color.ru S12 page). Wood-type use from catalogue p.19; species examples are derived. S12 is the thinner used in the official CTU dye schedules. |
| Thinner | S90 | 500–1000 %official | 500–1000 %official | Slow — staining coarse-pored woods (e.g. oak, ash); also big panels or a hot shop: gives the stain time to level out without blotches or lap marks.Coarse-pored wood and slow evaporation from catalogue p.19 and dealer S90 page; species examples and 'big panels / heat' are derived. |
| Thinner | LZC97 | 500–1000 %official | 500–1000 %official | Listed on the official page; no product description for LZC97 found.Missing from the dealer's mixing table. |
| Thinner | WATER (deionised) | 500–1000 %official | 500–1000 %official | Water-cut stain: penetrates deeper and pops the grain more; where you want minimal solvent.Deionised (distilled) water only — tap water makes the dye flocculate and hurts colour stability in the can. Raise the grain with water, dry and denib before a water stain. |
| Additive | CFS1 | 0–200 %official | 0–200 %official | Binder for the solvent-cut stain (S10/S12/S90): locks the dye down so the next primer coat drags/bleeds it less.Solvent/water assignment of CFS1/CFH1 is inferred: the dealer labels them 'solvent / water' in the opposite order to the codes, but the official schedules pair CFS1 with S12 and CFH1 with water, and Technocolor codes use S = solvent, H = water. |
| Additive | CFH1 | 0–200 %official | 0–200 %official | Binder for the water-cut stain. |
| Additive | CFS1 / S12 | — | — | Analogue: 'Raised-panel doors (PU)' schedule — written for CTU, not CLT2; 80–100 g/m², 5 min at 20–25 °C, then PTS20 PU primer. |
| Additive | CFS1 / S12 | — | — | Analogue: 'Mouldings and frames (UV)' schedule — written for CTU; 80 g/m², 5 min at 25–30 °C, then VTS40041 UV primer. |
| Additive | CFH1 / WATER | — | — | Analogue: water schedule (CTH) — 400 % CFH1 exceeds the 0–200 % official limit for CLT2; stay at ≤200 % with CLT2. |
Percentages are per 100 parts of component A.
Characteristics
- Viscosity
- 24 ± 2 not stated (almost certainly s, flow cup)dealer
- Working spray viscosity
- 10–13 s DIN4recommended
- Pot life
- not applicable (1K, no hardener) — mixed solvent stain keeps in a closed can; water-cut stain: mix what you use in a shiftrecommended
- Drying · Conditions
- 20–25 °C (PU schedules); 25–30 °C in the UV mouldings schedule (5 min)
- Drying · Before primer (min) · Solvent cut
- 5 minschedule
- Drying · Before primer (min) · Water cut
- 20 minschedule
- Drying · Derived guidance
- Solvent-cut (S10/S12): 5–15 min, slow S90: 15–30 min; water-cut: 20–40 min at 20 °C, longer in cold/humid shop — must be fully dry (no cool/damp feel) before sealingrecommended
Colours
- CLT2 · orange
Application
HVLP
- Consumption
- 80–100 g/m²official
- Nozzle
- 1–1.3 mmrecommended
- Pressure · air
- 1.5–2 bar at gun inlet, trigger pulledrecommended
- Pressure · fluid
- gravity cup / pressure pot 0.3–0.6 barrecommended
- Spray viscosity
- 10–13 s DIN4recommended
- Coats
- 1 even wet coat; a 2nd light coat only to deepen/correct colourrecommended
- Flash-off
- 5–15 (S10/S12), 15–30 (S90), 20–40 (water) at 20 °Crecommended
- Recoat
- Prime with the chosen PU/acrylic/UV primer once fully dry; first primer coat as a light mist pass so it does not lift the dyerecommended
- Sanding between coats
- Do not sand the stain itself — sand only after the first primer coat (P240–P320)recommended
Gun 15–20 cm from the work, 50 % overlap, steady pace; do edges and profiles first, then the face, so you don't double-coat the flat. recommended
Conventional spray
- Consumption
- 80–100 g/m²official
- Nozzle
- 1–1.2 mmrecommended
- Pressure · air
- 2–3 barrecommended
- Spray viscosity
- 10–13 s DIN4recommended
- Coats
- 1 wet coatrecommended
Airmix (air-assisted airless)
- Consumption
- 80–100 g/m²official
- Nozzle
- 0.18–0.23 mm (≈ 07–09 thou), fine fan 20–40°recommended
- Pressure · fluid
- 3–6 barrecommended
- Pressure · air
- 0.5–1.5 barrecommended
- Spray viscosity
- 10–13 s DIN4recommended
Airless
- Suitability
- not recommendedrecommended
Not recommended: even the smallest airless tip floods a thin stain — blotches and runs.
Dipping
- Suitability
- possible with binder-free or lightly bound solvent/water mix; test firstrecommended
Brush
- Suitability
- small areas / touch-up only; wipe off excess with a dry brush or rag along the grainrecommended
Process and compatibility
- Substrate preparation
- Wood moisture 8–14 %. Final sand P150–P220 on flats (profiles with K60–K80 pads). Coarser grit = darker stain, finer = lighter, so sand every part of a job the same. For a water stain, raise the grain with water first, dry and denib.source
- Goes over
- bare sanded wood (veneer, solid)
- Sanding
- Never sand the stain coat; sand only the primer (P240–P320 flat, K120 profile)schedule
- Temperature and humidity
- Wood moisture 8–14 %, shop RH 40–75 % (glossary). Stain drying in the analogous official schedules: 20–25 °C (PU schedules) or 25–30 °C (UV mouldings schedule).source
- Don'ts
- Don't cut with tap water — deionised only.
- Don't flood it on — 80–100 g/m², or it blotches.
- Don't go above 200 % binder.
- Don't prime over stain that isn't fully dry, especially water-cut.
- Don't sand the stain coat.
Storage
- Packaging
- 1 L,5 Ldealer
Sources
Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).
- official properties, method, consumption, thinners & binder %
- dealer: properties, use, mixing table, viscosity A 24±2 at 20 °C, deionised-water note, MILESI, packaging
- analogous dye schedule CTU+CFS1 200%+S12 500%
- analogous dye schedule CTU+CFS1 150%+S12 500%
- analogous water dye schedule CTH+CFH1 400%+water 1000%
- application method descriptions
- grain raising, grit vs stain darkness
- wood moisture 8–14 %, RH 40–75 %, water vs solvent dye behaviour
- S90 slow thinner for coarse-pored wood
Not covered by the sources
- solids_pct (not published)
- density
- viscosity unit/cup type for '24±2' (dealer gives number only)
- LZC97 — no product description anywhere
- lightfastness rating
- shelf life and storage temperature
- no official finishing schedule names CLT2 (only CTU/CTH analogues)
- no TDS/SDS PDF found online
- CFS1/CFH1 solvent-vs-water assignment inferred (dealer label order conflicts)
- unverified search-snippet claim (interwood.su, page returned HTTP 500): Kromolux can be sprayed over primer when solvent-cut and added to lacquer at 1–5 % — not recorded as data