Skip to content
Stains and dyesDye

CLT2

CLT2 Kromolux dye concentrate, orange

Concentrated transparent wood dye (stain). Gives an even, uniform colour and lets you go dark while keeping the wood see-through. Cuts with water or with solvent, and can be used with or without a binder. All dyes in the series intermix in any ratio to hit the target shade.

  • Colouring all kinds of wood species (veneer and solid)
  • Evening out colour variation, enriching or changing the wood colour
  • Base shade for blending with other CLT dyes

Mix calculator

g
Thinner750.0 %

When: Fast thinner — staining fine-pored woods (e.g. beech, birch, maple, alder).

Additive

Ratio 100 : 750.0

ComponentWeigh out
CLT2part A58.8 g
S10Thinner441 g
Total500 g

Covers roughly 5.56 m² at 90 g/m².

Pot life of the mix: not applicable (1K, no hardener) — mixed solvent stain keeps in a closed can; water-cut stain: mix what you use in a shift.

Ask about CLT2

Answers are based on the CLT2 data and the products it mixes with.

Questions and answers are stored to improve the assistant and prevent abuse; the question text is processed by Anthropic (USA). Privacy policy

Mixing matrix

  • S10Thinner
    % by weight: 500–1000 %official% by volume: 500–1000 %official

    Fast thinner — staining fine-pored woods (e.g. beech, birch, maple, alder).

    SG 0.790 ± 0.01; also used to flush equipment (t-color.ru S10 page). 'Fine-pored wood' use from catalogue p.19; species examples are derived. Dealer labels S10 'thinner for polyester'.

  • S12Thinner
    % by weight: 500–1000 %official% by volume: 500–1000 %official

    Medium evaporation — staining medium-pored woods (e.g. cherry, walnut).

    Nitro thinner, suitable for cutting dyes (t-color.ru S12 page). Wood-type use from catalogue p.19; species examples are derived. S12 is the thinner used in the official CTU dye schedules.

  • S90Thinner
    % by weight: 500–1000 %official% by volume: 500–1000 %official

    Slow — staining coarse-pored woods (e.g. oak, ash); also big panels or a hot shop: gives the stain time to level out without blotches or lap marks.

    Coarse-pored wood and slow evaporation from catalogue p.19 and dealer S90 page; species examples and 'big panels / heat' are derived.

  • LZC97Thinner
    % by weight: 500–1000 %official% by volume: 500–1000 %official

    Listed on the official page; no product description for LZC97 found.

    Missing from the dealer's mixing table.

  • WATER (deionised)Thinner
    % by weight: 500–1000 %official% by volume: 500–1000 %official

    Water-cut stain: penetrates deeper and pops the grain more; where you want minimal solvent.

    Deionised (distilled) water only — tap water makes the dye flocculate and hurts colour stability in the can. Raise the grain with water, dry and denib before a water stain.

  • CFS1Additive
    % by weight: 0–200 %official% by volume: 0–200 %official

    Binder for the solvent-cut stain (S10/S12/S90): locks the dye down so the next primer coat drags/bleeds it less.

    Solvent/water assignment of CFS1/CFH1 is inferred: the dealer labels them 'solvent / water' in the opposite order to the codes, but the official schedules pair CFS1 with S12 and CFH1 with water, and Technocolor codes use S = solvent, H = water.

  • CFH1Additive
    % by weight: 0–200 %official% by volume: 0–200 %official

    Binder for the water-cut stain.

  • CFS1 / S12Additive

    Analogue: 'Raised-panel doors (PU)' schedule — written for CTU, not CLT2; 80–100 g/m², 5 min at 20–25 °C, then PTS20 PU primer.

  • CFS1 / S12Additive

    Analogue: 'Mouldings and frames (UV)' schedule — written for CTU; 80 g/m², 5 min at 25–30 °C, then VTS40041 UV primer.

  • CFH1 / WATERAdditive

    Analogue: water schedule (CTH) — 400 % CFH1 exceeds the 0–200 % official limit for CLT2; stay at ≤200 % with CLT2.

Percentages are per 100 parts of component A.

Characteristics

Viscosity
24 ± 2 not stated (almost certainly s, flow cup)dealer
Working spray viscosity
10–13 s DIN4recommended
Pot life
not applicable (1K, no hardener) — mixed solvent stain keeps in a closed can; water-cut stain: mix what you use in a shiftrecommended
Drying · Conditions
20–25 °C (PU schedules); 25–30 °C in the UV mouldings schedule (5 min)
Drying · Before primer (min) · Solvent cut
5 minschedule
Drying · Before primer (min) · Water cut
20 minschedule
Drying · Derived guidance
Solvent-cut (S10/S12): 5–15 min, slow S90: 15–30 min; water-cut: 20–40 min at 20 °C, longer in cold/humid shop — must be fully dry (no cool/damp feel) before sealingrecommended

Colours

  • CLT2 · orange

Application

HVLP

Consumption
80–100 g/m²official
Nozzle
1–1.3 mmrecommended
Pressure · air
1.5–2 bar at gun inlet, trigger pulledrecommended
Pressure · fluid
gravity cup / pressure pot 0.3–0.6 barrecommended
Spray viscosity
10–13 s DIN4recommended
Coats
1 even wet coat; a 2nd light coat only to deepen/correct colourrecommended
Flash-off
5–15 (S10/S12), 15–30 (S90), 20–40 (water) at 20 °Crecommended
Recoat
Prime with the chosen PU/acrylic/UV primer once fully dry; first primer coat as a light mist pass so it does not lift the dyerecommended
Sanding between coats
Do not sand the stain itself — sand only after the first primer coat (P240–P320)recommended

Gun 15–20 cm from the work, 50 % overlap, steady pace; do edges and profiles first, then the face, so you don't double-coat the flat. recommended

Conventional spray

Consumption
80–100 g/m²official
Nozzle
1–1.2 mmrecommended
Pressure · air
2–3 barrecommended
Spray viscosity
10–13 s DIN4recommended
Coats
1 wet coatrecommended

Airmix (air-assisted airless)

Consumption
80–100 g/m²official
Nozzle
0.18–0.23 mm (≈ 07–09 thou), fine fan 20–40°recommended
Pressure · fluid
3–6 barrecommended
Pressure · air
0.5–1.5 barrecommended
Spray viscosity
10–13 s DIN4recommended

Airless

Suitability
not recommendedrecommended

Not recommended: even the smallest airless tip floods a thin stain — blotches and runs.

Dipping

Suitability
possible with binder-free or lightly bound solvent/water mix; test firstrecommended

Brush

Suitability
small areas / touch-up only; wipe off excess with a dry brush or rag along the grainrecommended

Process and compatibility

Substrate preparation
Wood moisture 8–14 %. Final sand P150–P220 on flats (profiles with K60–K80 pads). Coarser grit = darker stain, finer = lighter, so sand every part of a job the same. For a water stain, raise the grain with water first, dry and denib.source
Goes over
bare sanded wood (veneer, solid)
Sanding
Never sand the stain coat; sand only the primer (P240–P320 flat, K120 profile)schedule
Temperature and humidity
Wood moisture 8–14 %, shop RH 40–75 % (glossary). Stain drying in the analogous official schedules: 20–25 °C (PU schedules) or 25–30 °C (UV mouldings schedule).source
Don'ts
  • Don't cut with tap water — deionised only.
  • Don't flood it on — 80–100 g/m², or it blotches.
  • Don't go above 200 % binder.
  • Don't prime over stain that isn't fully dry, especially water-cut.
  • Don't sand the stain coat.

Storage

Packaging
1 L,5 Ldealer

Mixed into

CFH1 / CFS1 / CLT10 / CLT3 / LZC97

Sources

Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).

Not covered by the sources
  • solids_pct (not published)
  • density
  • viscosity unit/cup type for '24±2' (dealer gives number only)
  • LZC97 — no product description anywhere
  • lightfastness rating
  • shelf life and storage temperature
  • no official finishing schedule names CLT2 (only CTU/CTH analogues)
  • no TDS/SDS PDF found online
  • CFS1/CFH1 solvent-vs-water assignment inferred (dealer label order conflicts)
  • unverified search-snippet claim (interwood.su, page returned HTTP 500): Kromolux can be sprayed over primer when solvent-cut and added to lacquer at 1–5 % — not recorded as data