Skip to content
Stains and dyesDye

CLT54

CLT54 Kromolux dye concentrate, Anegre

Highly concentrated transparent dye (binder-free stain) from Milesi's Kromolux series in Anegre (named after the African anegre veneer — a pale golden-beige wood tone; check the exact shade against a dealer sample). Very clear and even; at higher strength it goes dark while staying transparent. Dilutes with water or solvent, with or without a binder.

  • Staining all kinds of timber, veneer and solid
  • Furniture, fronts, mouldings and frames, general wooden articles
  • Toning and evening out colour variation under PE, PU and NC lacquers

Mix calculator

g
Thinner750.0 %

When: Slow — open-pored timber (oak, ash), large panels, hot shop: stays wet longer, fewer blotches and lap marks.

Additive

Ratio 100 : 750.0

ComponentWeigh out
CLT54part A58.8 g
S90Thinner441 g
Total500 g

Covers roughly 5.56 m² at 90 g/m².

Pot life of the mix: not applicable — single-component, no reaction; keep diluted mix closed and use within the shift.

Ask about CLT54

Answers are based on the CLT54 data and the products it mixes with.

Questions and answers are stored to improve the assistant and prevent abuse; the question text is processed by Anthropic (USA). Privacy policy

Mixing matrix

  • S10Thinner
    % by weight: 500–1000 %dealer% by volume: 500–1000 %dealer

    Fast, strong thinner — stains on fine-pored timber per the catalog table (beech, birch, maple, alder are our examples).

    Thinner selection per the Technocolor 2025–2026 catalog thinner table. S10 is also the gun-cleaning solvent per its official page.

  • S12Thinner
    % by weight: 500–1000 %dealer% by volume: 500–1000 %dealer

    Medium evaporation — medium-pored timber (cherry, walnut, tight ash); the default for a solvent-borne stain.

    S12 is the dye thinner per its official page, and it is the thinner in the official schedules' CTU (transparent dye) steps (the anegri-veneer schedule with pigment CPS uses S90; water dye CTH uses water).

  • S90Thinner
    % by weight: 500–1000 %official% by volume: 500–1000 %official

    Slow — open-pored timber (oak, ash), large panels, hot shop: stays wet longer, fewer blotches and lap marks.

    Dealer lists S90 as 'slow dye thinner'.

  • WATERThinner
    % by weight: 500–1000 %official% by volume: 500–1000 %official

    Water dilution — less odour/VOC, raises the grain more and dries much slower (Milesi TDS: 8 h at 20 °C vs. minutes on solvent).

    Deionised (distilled) water only — tap water makes the dye flocculate and lose colour stability (dealer note). Before a water stain, raise the grain with a damp sponge, dry and denib at P180–P220.

  • LZC97Thinner
    % by weight: 500–1000 %official% by volume: 500–1000 %official

    Listed by Technocolor as a thinner. The Milesi TDS uses LZC97 as a small-share co-solvent alongside the main thinner (see the TDS rows).

    LZC97's exact function is not documented by Technocolor; no product page.

  • CFS1Additive
    % by weight: 0–200 %dealer% by volume: 0–200 %dealer

    Binder for the solvent-borne stain (with S10/S12/S90): locks the dye in, less bleeding/lifting when the sealer goes on, more even colour on end grain.

    Role: binder. CFS1 = solvent-borne and CFH1 = water-borne follows from the schedules (CFS1 paired with S12, CFH1 with water); the dealer's ОР/ВР labels are listed in the opposite order.

  • CFH1Additive
    % by weight: 0–200 %dealer% by volume: 0–200 %dealer

    Binder for the water-diluted stain.

    0 % = plain dye stain; with binder the colour holds better under the sealer.

  • LZC97 / LZC1000Thinner
    % by weight: CLT 1 : LZC97 0.5 : LZC1000 9.5 (≈ LZC97 50 % + LZC1000 950 %)datasheet

    Milesi's suggested solvent dilution. LZC1000 is a Milesi code; in the Technocolor line its place is taken by S10/S12/S90 per the official page.

  • LZC97 / WATERThinner
    % by weight: CLT 1 : LZC97 1 : water 14 (≈ LZC97 100 % + water 1400 %)datasheet

    Milesi's suggested water dilution.

  • LZC1000 / LZC1024 / LZC97 / LTC5 / WATERThinner
    % by weight: 500–800 %datasheet

    Milesi TDS: manual spray, fixed automatic airmix/airless, swinging-arm guns — 500–800 %; rotating carousel — 700–1500 %.

  • CFS1 / S12Additive
    % by weight: CFS1 200 % + S12 500 %schedule

    Raised-panel doors (PU): stain 80–100 g/m², 5 min at 20–25 °C, then PTS20+C25+S50 sealer.

    The finishing schedule names the CTU series (Technocolor universal transparent dyes), not CLT. CLT54 has no t-color.ru page, but its siblings CLT1–CLT18 sit in the same 'Universal dyes' section there with the same thinner/binder table as CTU (S10/S12/S90/water 500–1000 %, CFS1/CFH1 0–200 %), so the recipe is carried over as a guide; that mapping is our interpretation, not an explicit CLT54 instruction.

  • CFS1 / S12Additive
    % by weight: CFS1 150 % + S12 500 %schedule

    Mouldings and frames (UV): stain 80 g/m², 5 min at 25–30 °C, then VTS40041 UV sealer.

    The finishing schedule names the CTU series (Technocolor universal transparent dyes), not CLT. CLT54 has no t-color.ru page, but its siblings CLT1–CLT18 sit in the same 'Universal dyes' section there with the same thinner/binder table as CTU (S10/S12/S90/water 500–1000 %, CFS1/CFH1 0–200 %), so the recipe is carried over as a guide; that mapping is our interpretation, not an explicit CLT54 instruction.

  • CFH1 / WATERAdditive
    % by weight: CFH1 400 % + вода/water 1000 %schedule

    Open-pore oak kitchen fronts: stain 80–100 g/m², 20 min at 20–25 °C, PTS60+C26+S50 sealer.

    This schedule is written for the water dye CTH, not CLT; 400 % CFH1 exceeds CLT54's official 0–200 % — stay within 0–200 % for CLT54.

Percentages are per 100 parts of component A.

Characteristics

Viscosity
24 ± 2 s, 24 ± 2 s
Drying · Conditions
20 °C (TDS room-temperature schedule; RH not stated in the TDS)
Drying · Room temp (solvent)
30 s (LZC1000 thinner; printed 30")datasheet
Drying · Room temp (water)
8 h (water thinner)datasheet
Drying · IR drying 60 °C (solvent)
10 mindatasheet
Drying · IR drying 60 °C (water)
20 mindatasheet
Pot life
not applicable — single-component, no reaction; keep diluted mix closed and use within the shiftrecommended
Thixotropy
norecommended
Gloss
not applicable — no filmrecommended

Colours

  • CLT54 · Anegre

Application

HVLP

Nozzle
1–1.3 mmrecommended
Pressure · fluid
gravity cup, no fluid pressurerecommended
Pressure · air
1.5–2 bar inlet (gun trigger pulled); ≈0.5–0.7 bar at caprecommended
Spray viscosity
as diluted (500–1000 %), ~water-thin — do not thin to a cup timerecommended
Consumption
80–100 g/m² ready mixdealer
Coats
1 even full wet pass (2 light crossing passes on large panels); add colour by a second pass, not by floodingrecommended
Flash-off · Solvent
5 min at 20–25 °C (CFS1+S12 mix)schedule
Flash-off · Water
20 min at 20–25 °C (CFH1+water mix)schedule
Recoat · Sealer (solvent)
after 1 min (thinned with LZC1000)datasheet
Recoat · Sealer (waterborne)
after 8 h (thinned with water) at 20 °C; forced drying IR tunnel + warm air 60 °C = 20 mindatasheet
Sanding between coats
do not sand the stain coat itself; denib the first sealer coat at P240–P320recommended

Hold the gun square at 15–20 cm, 50 % overlap. On profiles do edges and recesses first, then the field. Stir the mix before filling.

Conventional spray

Nozzle
1–1.2 mmrecommended
Pressure · air
2–3 bar at gunrecommended
Consumption
80–100 g/m² ready mixdealer

Classic air spray — the mainstream method per the methods page (up to 40 % transfer).

Airmix (air-assisted airless)

Nozzle
0.18–0.23 mm (07–09 thou), narrow 20–40° fanrecommended
Pressure · fluid
4–8 barrecommended
Pressure · air
0.8–1.5 barrecommended
Consumption
10–20 g/m² (TDS figure — appears to be concentrate, see notes)datasheet

The Milesi TDS states 10–20 g/m² for automatic airmix — given the 500–800 % dilution this reads as concentrate, i.e. ~80–100 g/m² of ready mix.

Airless

Nozzle
0.18–0.23 mm (07–09 thou)recommended
Pressure · fluid
30–60 barrecommended
Consumption
10–20 g/m² (TDS figure, likely concentrate)datasheet

For hand work prefer airmix/HVLP — airless has a coarser fan and more blotch risk.

Automatic rotating spray

Consumption
5–20 g/m² (automatic rotating carousel, TDS)datasheet
Dilution %
700–1500 %datasheet

Milesi TDS: automatic rotating (carousel) spray machine — 5–20 g/m², 700–1500 % dilution. This is not electrostatic; the TDS does not mention electrostatic application.

Process and compatibility

Substrate preparation
Sand flats P150 → P180 → P220; profiles with sanding mats/sponges K60–K80schedule
Goes over
bare sanded wood
Sanding
Never sand the dyed surface directly; sand the first sealer coat P240–P320 (flats) / K120 (profiles) per schedulerecommended
Temperature and humidity
TDS data at 20 °C (room temperature); RH not stateddatasheet
Don'ts
  • Don't dilute with tap water — deionised only
  • Don't exceed 200 % CFS1/CFH1 binder
  • Don't flood the surface — make a second light pass instead
  • Don't sand the bare dye coat — sand the sealer
  • Don't seal a water-diluted stain before it is fully dry (TDS: ~8 h at 20 °C or 20 min at 60 °C)

Storage

Shelf life
8 months from delivery (series TDS; CLT54 not named)datasheet
Storage temperature
18–25 °C, tightly closed, protected from moisturedatasheet
Packaging
1 Ldealer

Safety: Composition and hazard class are not published (no CLT54 SDS found). Treat the concentrate and S10/S12/S90 mixes as flammable: spray in an extracted booth, no ignition sources, A2P2 respirator and nitrile gloves; keep solvent rags in a closed metal bin.

Sources

Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).

Not covered by the sources
  • solids_pct (blank in Milesi TDS, not on official/dealer pages)
  • lightfastness rating (no sourced figure)
  • hardness/elasticity/chemical resistance — not applicable to a binder-free dye on its own
  • LZC97 function and Technocolor product page (no official or dealer page)
  • CFS1/CFH1 product pages and their own data (no official/dealer page found)
  • consumption discrepancy: dealer / sibling-official (CLT4) 80–100 g/m² (ready mix) vs Milesi TDS 5–20 g/m² (basis not stated, apparently concentrate)
  • SDS / hazard classification for CLT54
  • no Technocolor-issued TDS for CLT54; data sheet used is Milesi's (IVM) CLT series TDS, rev. I, Oct 2006
  • CLT not covered in Technocolor 2025–2026 catalog (only CTU/CPS/CTH dyes)
  • no official t-color.ru page for CLT54; LZC97 and water-as-thinner on the official side come from sibling CLT4
  • CLT54 absent from the 2006 Milesi TDS colour list — density/SG unknown; series viscosity/drying assumed to apply
  • electrostatic suitability not documented (TDS covers manual, airmix, airless, swinging-arm and rotating-carousel spray only)