ATL20 SG two-component acrylic lacquer, 40 gloss (semi-gloss)

Two-component clear acrylic lacquer (cured with an aliphatic isocyanate hardener) — about as water-clear and lightfast as it gets, giving a smooth, pleasant-to-the-touch film. High chemical/physical resistance, non-yellowing, wets the wood well and keeps the pores open and crisp on open-pore finishes. The go-to topcoat for kitchen doors and bathroom furniture, including open-pore and decapé (liming) effects.

  • kitchen cabinet doors (solid wood, veneer, MDF)
  • bathroom furniture and humid rooms
  • open-pore finishing of oak and other ring-porous timbers
  • clear topcoat over decapé/limed and patinated finishes
  • clear topcoat over enamels and special effects (metallic enamel, Frost, Drops, Blur, shabby-chic)
  • interior doors, architraves, wall and slat panels, handrails, T&G cladding — interior only

Mix calculator

g
Hardener20.0 %

AC40: 20.0 % — fixed by the datasheet

When: Dealer's mixing table

Thinner35.0 %

When: Universal, medium evaporation — default choice, vertical work, 18–25 °C.

Additive

Ratio 100 : 20.0 : 35.0

ComponentWeigh out
ATL20 SGpart A323 g
AC40Hardener64.5 g
S50Thinner113 g
Total500 g

Covers roughly 3.33 m² at 150 g/m².

Pot life of the mix: 6 h.

Ask about ATL20 SG

Answers are based on the ATL20 SG data and the products it mixes with.

Questions and answers are stored to improve the assistant and prevent abuse; the question text is processed by Anthropic (USA). Privacy policy

Mixing matrix

  • AC40Hardener
    % by weight: 10–20 (typ. [object Object]) %catalog

    Standard hardener (aliphatic, non-yellowing). Mix by weight on scales.

    Dealer table (t-colormarket) gives a fixed 20 % by weight and volume.

  • AC41Hardener
    % by weight: 10–20 %catalog

    Alternative to AC40 — listed on the official ATL20 M page and the 2019 catalog; on the catalog hardener chart AC41 sits slightly faster/harder and slightly less non-yellowing than AC40.

    For ATL20 SG AC41 is not on the official/dealer page — only the 2019 catalog lists it (as C41) for the whole ATL20 line. Prefer AC40.

  • AC40Hardener
    % by weight: 20 %dealer% by volume: 20 %dealer

    Dealer's mixing table

  • AC40Hardener
    % by weight: 20 %schedule

    Official schedules: open-pore oak kitchen doors (acrylic) and decapé oak kitchen doors (acrylic)

    Schedules write 'C40' — the legacy name of AC40 (the 2019 catalog lists ATL20 hardeners as C40/C41).

  • S50Thinner
    % by weight: 30–40 (typ. [object Object]) %catalog

    Universal, medium evaporation — default choice, vertical work, 18–25 °C.

    Catalog: S50 is for PU/acrylic primers, matt lacquers and enamels. Doesn't change cure time.

  • S80Thinner
    % by weight: 30–40 %catalog

    Slow — above ~25 °C, large flat panels, and deep-matt grades (UM) for an even matt without clouding.

    Catalog: S80 is for deep-matt and high-gloss materials. More dust pick-up and sag risk; doesn't change cure time.

  • S80Thinner
    % by weight: 30 %schedule

    Open-pore oak schedule: ATL20 100 / C40 20 / S80 30 / CTS 0.5; 150 g/m², dry 1.5 h at 30–35 °C

  • S50Thinner
    % by weight: 40 %schedule

    Decapé oak schedule: ATL20 100 / C40 20 / S50 40; 150 g/m², dry 1.5 h at 30–35 °C

  • CTS1 / CTS2 / CTS3 / CTS4 / CTS9Additive
    % by weight: 0.5 %schedule

    Additive in the lacquer coat of the open-pore oak schedule

    What CTS is isn't stated in any available source (possibly a toner or flow/slip additive). Check with Technocolor.

Percentages are per 100 parts of component A.

Characteristics

Solids
28 ± 1 %dealer
Viscosity
40 ± 3 sdealer
Spray viscosity (est.)
16–20 s DIN4 (VZ-4) after 30–40 % S50/S80 + hardenerrecommended
Density
≈0.93–0.97 g/cm³ (part A); mix ≈0.90–0.93 g/cm³recommended
Gloss
40 ± 3 GU (gloss units, 60°)dealer
Pot life
6 hdealer
Drying · Dust-free
≈10–15 minrecommended
Drying · Touch-dry
20 mindealer
Drying · Sand or stack
3–4 h at 20 °C; 1.5 h after forced drying at 30–35 °C hrecommended
Drying · Full cure
8 hdealer
Drying · Forced drying
30–35 °C, 1.5 hschedule
Drying · Conditions
20 °C
Hardness
high physical/chemical resistance, abrasion-resistant, washable (no numeric hardness published)dealer
Lightfastness
non-yellowing, maximally lightfast clearcatalog
Chemical resistance
high physical-chemical resistance; suitable for kitchens and bathroomscatalog
Elasticity
elastic (acrylic lacquers have high elasticity per Technocolor)official
Thixotropy
norecommended
Service life
> 15 years service life claimeddealer
Interior or exterior
interior onlydealer

Colours

  • ATL20 SG · clear (colourless)

Application

HVLP

Nozzle
1.3–1.5recommended
Pressure · air
inlet 2.0–2.2 bar (trigger pulled); ≤0.7 bar at the caprecommended
Pressure · fluid
gravity cup; 0.5–1.0 bar if pressure potrecommended
Spray viscosity
16–20 s DIN4 (VZ-4) at 20 °Crecommended
Consumption
150 g/m²catalog
Wet film
≈150–165 µm wet → ≈25–35 µm dry per 150 g/m² coatrecommended
Coats
1 coat over a properly primed and sanded surfacedealer
Recommended coats
1 coat on doors/panels; 2 coats on worktop-adjacent kitchen/bath partsrecommended
Flash-off
≈10–15 min before forced dryingrecommended
Recoat
after 3–4 h at 20 °C (or 1.5 h at 30–35 °C), after denibbingrecommended
Sanding between coats
P320–P400 or grey/fine pad (e.g. 07448), light denib onlyrecommended
Gun setup
fan fully open, needle ≈2 turns, distance 15–20 cm, overlap 50–75 %, ~10–13 CFM compressor deliveryrecommended

Methods page: conventional/air spray is the universal route, ~40 % transfer efficiency. Matt ATL20 grades — never sand or polish the final coat.

Conventional spray

Nozzle
1.4–1.6recommended
Pressure · air
2.5–3.5 bar at the gunrecommended
Pressure · fluid
gravity/suction; 1.0–1.5 bar if pressure potrecommended
Spray viscosity
16–20 s DIN4recommended
Consumption
150 g/m²catalog

Air spray is the application method stated by the catalog and official page.

Airmix (air-assisted airless)

Nozzle
tip 09–11 thou (0.23–0.28 mm), 20–40° fanrecommended
Pressure · fluid
≤20 bar (start ≈10–15 bar, raise until the fan tails close)recommended
Pressure · air
1–2 barofficial
Spray viscosity
≈20–22 s DIN4 (thinner at the low end of the official range, ~30 %)recommended
Consumption
150 g/m²catalog

Production option; ATL20 product pages state only 'spray'.

Brush

Consumption
150 g/m²dealer
Dilution for brushing
≈30 % S80recommended

Dealer: brushing is also acceptable — small jobs/touch-up only; thin less (≈30 % S80 — bottom of the official range, slow thinner) so it doesn't drag. Won't level like a sprayed coat.

Airless

Recommendation
not recommendedrecommended

Not recommended for this topcoat — the methods page positions airless for primers on large flat panels; airmix is better for finishing.

Process and compatibility

Substrate preparation
Sand flat surfaces P150→P180→P220, profiles with K60/K80 pads; prime (ATS20, or enamel APL20 for decapé); sand primer P240→P280→P320 + padsschedule
Goes over
ATS20 / APL20 / CQS / APL80093 / APL80094 / APL80048 / HTL10001 / PPS50 / PPS20 / PTS20 / APS20106 / PPS400XX / CGS
Goes under
CQS
Sanding
Primer P240–P320 before lacquer; between lacquer coats P320–P400 / fine pad; never sand or polish the final matt coatrecommended
Temperature and humidity
18–25 °C, RH 50–70 %; material and substrate ≥ 18 °Crecommended
Don'ts
  • don't use outdoors — interior-only lacquer
  • don't use the mix past its 6 h pot life at 20 °C
  • don't sand or polish the final matt coat
  • don't swap in aromatic PU hardeners (PC…) — they yellow
  • don't lay more than ~150 g/m² per pass — sheen goes uneven and it can sag

Storage

Packaging
1 L, 5 L, 25 Ldealer

Safety: Solvent-borne 2K with isocyanate hardener: flammable; spray in a ventilated booth with an A2P2 respirator (or air-fed mask), nitrile gloves and eye protection. Keep away from ignition sources. Don't seal leftover catalysed mix airtight.

Sources

Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).

Not covered by the sources
  • no Technocolor technical data sheet (ТДС) PDF found online
  • shelf life and storage temperature not published
  • density not published (derived estimate only)
  • dust-free time not published (derived)
  • hardness / elasticity / chemical resistance have no numeric test values
  • no sourced nozzle/pressure data — all spray settings derived
  • purpose of additive CTS (0.5 % in the open-pore schedule) unknown
  • no official t-color.ru product page for ATL20 SG (only catalog + dealer); official mix ranges taken from the family catalog card