Skip to content
AcrylicPrimer

ATS20

ATS20 Clear acrylic primer (sealer)

Two-pack (2K, cured with AC40) clear acrylic primer/sealer for wood. Good physical and chemical resistance, non-yellowing over time, and it brings out the grain in open-pore finishes. Wets out very well and sands easily; a good pick for coarse-grained woods (oak, ash) where lightfastness and clean colour matter. Can also go over enamels ahead of a patina. The dealer reports a reformulated version with better wetting (no bubbles or pinholes on ash veneer), pores sealed and clearly defined once dry, and no change in sandability or in the stain colour under the primer.

  • Kitchen and bathroom furniture, any wood species (TDS, dealer)
  • Open-pore finishing of coarse-grained woods (oak, ash)
  • Light-coloured furniture where non-yellowing matters
  • Interior doors, cabinet fronts, mouldings, handrails, slatted and wall panels, T&G boarding; solid wood, veneer and plywood
  • Primer over enamel ahead of a patina
  • Washcoat/barrier coat under epoxy pours

Mix calculator

g
Hardener20.0 %

AC40: 20.0 % — fixed by the datasheet

When: Standard hardener - the only one on the official page and at the dealer. Fixed 20 %, mix by weight on scales.

Thinner35.0 %

When: Default thinner: medium evaporation rate, 18–25 °C, vertical surfaces.

Ratio 100 : 20.0 : 35.0

ComponentWeigh out
ATS20part A323 g
AC40Hardener64.5 g
S50Thinner113 g
Total500 g

Covers roughly 3.33 m² at 150 g/m².

Pot life of the mix: 6 h.

Ask about ATS20

Answers are based on the ATS20 data and the products it mixes with.

Questions and answers are stored to improve the assistant and prevent abuse; the question text is processed by Anthropic (USA). Privacy policy

Mixing matrix

  • AC40Hardener
    % by weight: 20 %official% by volume: 20 %official

    Standard hardener - the only one on the official page and at the dealer. Fixed 20 %, mix by weight on scales.

    Aliphatic; the most yellowing-resistant Technocolor hardener (catalog p.19). The 2017 TDS and the schedules call it C40 - the older name of AC40 (same description, 'PU hardener for acrylic coatings'). Workshop notes: AC40 fixed at 20 %.

  • AC41Hardener
    % by weight: 20 %catalog

    Alternative to AC40, listed only in the 2025-26 catalog (not on the official page or at the dealer).

    On the catalog chart AC41 is also aliphatic, ≈36 % solids, a touch faster/harder and slightly less non-yellowing than AC40. No % by volume published.

  • S50Thinner
    % by weight: 30–40 (typ. 35) %official% by volume: 30–45 %official

    Default thinner: medium evaporation rate, 18–25 °C, vertical surfaces.

    Does not change cure time (workshop).

  • S80Thinner
    % by weight: 30–40 %official% by volume: 30–45 %official

    Slow: above ~25 °C, large panels, when you want more open time and flow.

    More sag and dust-pickup risk (workshop).

  • S30Thinner
    % by weight: 30–40 %official% by volume: 30–45 %official

    Fast thinner (catalog p.19) - listed only on the official page; for a cold shop below ~18 °C or small parts.

    Fast flash can give dry spray and poorer pore wetting - avoid in warm conditions.

  • AC40Hardener
    % by weight: 20 %schedule

    The schedule writes the hardener as 'C40 : 20%' - the older name of AC40 (the 2017 TDS uses it too), not a typo.

  • S50Thinner
    % by weight: 30 %schedule

    Schedule 'Open-pore oak kitchen fronts (acrylic)': ATS20 100 / AC40 20 / S50 30, 150 g/m², dry 1.5 h at 30–35 °C.

  • AC40Hardener
    % by weight: 20 %workshop

    Thinned washcoat.

  • S50 / S80Thinner
    % by weight: 60–90 (typ. 75) %workshop

    Washcoat under epoxy or as a sealing first coat: ~70 g/m², 2 light coats, recoat after 20–30 min, wait 24 h before epoxy.

    Outside Technocolor's 30–40 % range - this is the owner's own practice. The workshop note gives no thinner code; S50/S80 assumed from the main recipe.

Percentages are per 100 parts of component A.

Characteristics

Solids
30 ± 1 %dealer
Viscosity
45 ± 5 sdealer
Pot life
6 hdealer
Drying · Dust-free
20 minworkshop
Drying · Touch-dry
20 mindealer
Drying · Sand or stack
4 hdealer
Drying · Full cure
6 hdealer
Drying · Conditions
20 °C
Lightfastness
non-yellowingofficial
Chemical resistance
high physical-chemical resistanceofficial
Elasticity
elastic enough for high-humidity roomsdealer
Sandability
easy to sandcatalog
Wetting
excellent wettingcatalog
Thixotropy
norecommended
Components
2K: part A + AC40 hardenerofficial
Interior or exterior
interior onlydealer
Part B solids %
38 ± 1 %datasheet
Mix solids %
32 ± 1 %datasheet
Density
0.96 ± 0.01 g/cm³ (specific gravity)datasheet
Standards
ТУ 2313-001-86718770-2013; СГР RU.77.01.34.008.E.003212.08.14 (29.08.2014)datasheet

Application

HVLP

Nozzle
1.3–1.5 (typ. 1.4) mmrecommended
Pressure · air
1.8–2.2 barrecommended
Spray viscosity
16–20 s DIN4 / VZ-4recommended
Consumption
150 g/m²official
Wet film
150–165 µmrecommended
Coats
1–2dealer
Flash-off
15–20 minrecommended
Recoat
sand and topcoat after 4 h at 20 °Cdealer
Sanding between coats
P280–P320, after 4 h (overnight if the paper clogs)workshop
Gun setup · Gun distance
15–20 cmrecommended
Gun setup · Overlap
50–75 %recommended
Gun setup · Fan
fully openrecommended
Gun setup · Air demand
10–13 CFMrecommended

Lay on a full wet coat so the primer gets into the pores, but don't let it pool in oak/ash grain. Go easy on verticals - it isn't thixotropic.

Conventional spray

Nozzle
1.4–1.6 (typ. 1.5) mmrecommended
Pressure · air
3–4 barrecommended
Spray viscosity
16–20 s DIN4recommended
Consumption
150 g/m²official

The official method is 'spraying'. Transfer efficiency up to 40 % (methods page).

Airmix (air-assisted airless)

Nozzle
tip 09–11 thou (0.23–0.28 mm), 20–40° fanrecommended
Pressure · fluid
8–15 barrecommended
Pressure · air
1–2 barrecommended
Spray viscosity
20–25 s DIN4recommended

Good for production runs; finish quality close to air spray.

Airless

Nozzle
tip 09–13 thou (0.23–0.33 mm)recommended
Pressure · fluid
80–120 barrecommended
Spray viscosity
25–35 s DIN4recommended

Fast, but easy to over-apply - keep to 150 g/m² for an open-pore look.

Electrostatic

Nozzle
as for the base system (HVLP 1.3–1.5 mm / airmix 09–11 thou)recommended

Chairs, legs, frame work. Test the mix's conductivity first.

Process and compatibility

Substrate preparation
flats P150–P180–P220 belt; profiles К60/К80 pads; stain (e.g. CGS, 80–100 g/m²) and wipe, dry 10 min at 20 °C before primingschedule
Goes over
CGS / CTU stain / bare wood / acrylic enamels (before patina)
Goes under
CQS / ATL20 / ATL20 SM / ATL50 / ATL90 / epoxy (workshop washcoat)
Sanding
P240–P320 after drying (4 h at 20 °C or 1.5 h at 30–35 °C)schedule
Temperature and humidity
18–25 °Crecommended
Don'ts
  • Don't use the mix past its 6 h pot life at 20 °C
  • Don't try to build a closed-pore finish with it - it's an open-pore primer
  • Don't sand before 4 h at 20 °C (the paper clogs)
  • Don't use it outdoors - interior only
Substrate prep (also)
sand P80–120 before priming, CTU stain → ATS20 → ATL20 SM 30 gloss

Storage

Packaging
1 L,5 L,25 Ldealer
Storage temperature
5–25 °Crecommended
Conditions
tightly closed metal can, protected from sunlight and precipitationdatasheet
Shelf life
8 monthsdatasheet

Safety: Technocolor TDS: use respiratory, hand and eye protection and workwear; keep away from children; dispose of waste at a licensed site, do not release to the environment. In addition (generic 2K PU/acrylic practice): AC40 (C40) is an isocyanate hardener - spray in an extracted booth with an A2/P2 or better respirator; material and thinners are flammable.

Used in finishing systems

Mixed into

AC40

Sources

Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).

Not covered by the sources
  • density of the catalysed/thinned mix (only part A, 0.96, published)
  • gloss of the cured primer
  • official storage temperature range
  • official spray viscosity, nozzle sizes and pressures (all application settings are derived)
  • % by volume for AC41 (catalog-only alternative hardener)
  • no Technocolor SDS for ATS20 found online (TDS found, 2017 edition)
  • conflict: thinner % by volume - official 30–45 %, dealer and TDS 35–45 %
  • conflict: thinner list - official S30/S50/S80, dealer/TDS/catalog S50/S80 only
  • conflict: hardener list - catalog AC40 or AC41, official/dealer AC40 only (TDS C40 = AC40)
  • conflict: solids part A - 30 ± 1 % (official dealer, TDS, catalog 30 %) vs 31 ± 1 % on mklnn.ru
  • conflict: mklnn.ru mix table gives S50 20–40 % (others 30–40 %)
  • TDS (2017) predates the dealer-reported reformulation; figures may differ for the current batch