VTL60095
VTL60095 UV-cure spray lacquer, 100 gloss (full gloss)
Clear UV-cure spray lacquer, full gloss (100 GU). Flows out very well, high clarity, good physical and chemical resistance. It does not dry on its own: it cures under UV lamps on a line, so you need a UV curing unit to use it.
- Full-gloss topcoat for furniture parts and fronts on a UV-cure line
- Topcoat over clear UV sealers (veneer, solid wood)
- Flat panels and profiled parts where you need to stack straight off the lamp
Mix calculator
Ratio 100 : 20.0
| Component | Weigh out |
|---|---|
| VTL60095part A | 417 g |
| S11Thinner | 83.3 g |
| Total | 500 g |
Covers roughly 4.55 m² at 110 g/m².
Pot life of the mix: not applicable — no pot life as such; keep the material away from daylight/UV, closed container.
Ask about VTL60095
Answers are based on the VTL60095 data and the products it mixes with.
Mixing matrix
- Hardener
No hardener — single-component UV lacquer.
- S11Thinner% by weight: 20 %schedule
Analogue from the official schedule: spray UV lacquer VTL30040 : S11 = 100 : 20 (mouldings, 150 g/m²). Not published for VTL60095 itself — a reference point, not a spec.
With thinner you must pre-dry at 30–35 °C for 5–10 min; all the solvent has to be out before the lamp. Note: the catalog thinner table lists S11 for polyester gloss lacquers, not UV; for UV materials it names S13/S30/S31.
- % by weight: 0–15 (typ. 10) %recommended
Only to trim spray viscosity. S31 by default (better levelling on gloss); S13/S30 if the line's pre-dry zone is short.
Don't use slow thinners (S70/S80/S100): solvent left in the film under the lamp causes bubbles, haze and poor adhesion.
| Role | Material | % by weight | % by volume | When |
|---|---|---|---|---|
| Hardener | — | — | No hardener — single-component UV lacquer. | |
| Thinner | S11 | 20 %schedule | — | Analogue from the official schedule: spray UV lacquer VTL30040 : S11 = 100 : 20 (mouldings, 150 g/m²). Not published for VTL60095 itself — a reference point, not a spec.With thinner you must pre-dry at 30–35 °C for 5–10 min; all the solvent has to be out before the lamp. Note: the catalog thinner table lists S11 for polyester gloss lacquers, not UV; for UV materials it names S13/S30/S31. |
| Thinner | S31 / S13 / S30 | 0–15 (typ. 10) %recommended | — | Only to trim spray viscosity. S31 by default (better levelling on gloss); S13/S30 if the line's pre-dry zone is short.Don't use slow thinners (S70/S80/S100): solvent left in the film under the lamp causes bubbles, haze and poor adhesion. |
Percentages are per 100 parts of component A.
Characteristics
- Gloss
- 100 GUofficial
- Flow
- excellent flow-outofficial
- Clarity
- high transparencyofficial
- Chemical resistance
- good physical-chemical resistance (no numeric rating published)official
- Components
- 1K — single component, no hardenerrecommended
- Pot life
- not applicable — no pot life as such; keep the material away from daylight/UV, closed containerrecommended
- Drying · Cure mechanism
- УФ-отверждение (UV cure) — category 'Материалы УФ отверждения'official
- Drying · Pre-dry flash-off
- 30–35 °C, 5–10 мин (5–10 min) before the UV lampsschedule
- Drying · UV cure
- 80–120 Вт (as printed), 3 lamps, belt 10 m/minschedule
- Drying · UV lamp type
- medium-pressure mercury (Hg) lamps; clear lacquer does not need Ga-doped lampsrecommended
- Drying · Sand or stack
- immediately after the lamps cool the part (minutes)recommended
- Drying · Conditions
- line, pre-dry 30–35 °C, then UV
Application
HVLP
- Consumption
- 100–120 g/m²official
- Nozzle
- 1.3–1.5 mmrecommended
- Pressure · air
- 2–2.2 barrecommended
- Spray viscosity
- 18–22 s DIN4 @20 °Crecommended
- Wet film
- 100–120 µmrecommended
- Coats
- 1 coatsrecommended
- Flash-off
- 5–10 minschedule
Gun at 15–20 cm, overlap 50–75 %, one full wet pass. Overspray won't dry in the booth under normal light — clean up straight away.
Conventional spray
- Consumption
- 100–120 g/m²official
- Nozzle
- 1.4–1.6 mmrecommended
- Pressure · air
- 3–4 barrecommended
- Spray viscosity
- 16–20 s DIN4 @20 °Crecommended
- Coats
- 1 coatsrecommended
- Flash-off
- 5–10 minschedule
Transfer efficiency is up to 40 % (methods page) — with an expensive UV lacquer HVLP or airmix makes more sense.
Airmix (air-assisted airless)
- Consumption
- 100–120 g/m²official
- Nozzle
- 0.23–0.28 mm (tip 09–11 thou, 20–40° fan)recommended
- Pressure · fluid
- 8–15 barrecommended
- Pressure · air
- 1–2 barofficial
- Spray viscosity
- 20–25 s DIN4 @20 °Crecommended
- Flash-off
- 5–10 minschedule
Best choice for production gloss finishing of panels on a line.
Electrostatic
- Consumption
- 100–120 g/m²official
- Nozzle
- 1.3–1.6 mm (air gun); airmix tips 09–11 thou as for the airmix entryrecommended
For profiled parts; confirm electrostatic suitability (conductivity) with a test.
Process and compatibility
- Substrate preparation
- Veneer/solid wood sanded P150–P220; then clear UV sealer coat(s), each lamp-cured; before the lacquer sand P240–P320 and de-dust.schedule
- Sanding
- before topcoat: P240, P280, P320 on the cured UV sealerschedule
- Temperature and humidity
- material and parts 18–25 °C, RH 50–70 %; pre-dry zone 30–35 °Crecommended
- Don'ts
- Don't send it to the lamps without pre-drying — you'll get bubbles and haze
- Don't store it or leave it in open containers in sunlight/daylight
- Don't apply over 2K PU/acrylic without an adhesion test
- Don't overload the film — a too-thick coat won't cure through
- Don't use slow thinners S70/S80/S100
Storage
- Storage temperature
- +5…+25 °C, dark, sealed original containerrecommended
Safety: Contains solvents and acrylate monomers: spray in a ventilated booth, wear a respirator, nitrile gloves and goggles; avoid skin contact (acrylates are skin sensitisers). UV lamps: protect eyes and skin, keep the tunnel shielded.
Sources
Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).
- official page: properties, spray 100–120 g/m², 100 gloss
- UV gloss schedule (curtain-coat VTL30100): sanding P240–P320, pre-dry 30–35 °C 5 min, UV 80–120 Вт ×3 at 10 m/min
- UV spray lacquer schedule (VTL30040 : S11 = 100 : 20, pre-dry 30–35 °C 5–10 min)
- UV parquet schedule (lamp cure settings, immediate next step after cure)
- application methods (air ≤40 % transfer, airmix ≤20 bar fluid / 1–2 bar air, electrostatic)
- dealer search — no product
Not covered by the sources
- Dealer page: t-colormarket.ru search for VTL60095 (and for 'VTL') returns no products — the shop does not stock the VTL UV line; no solids, viscosity, density or drying data
- No Technocolor TDS PDF found (web search budget exhausted; no hits in local catalogs/transcripts)
- Not in the 2025-2026 catalog transcripts
- solids_pct, viscosity (delivery), density — unknown
- Official thinner type and ratio for VTL60095 itself — only schedule analogue (VTL30040 : S11 20 %) and derived S31/S13/S30 range
- UV dose (mJ/cm²) / exact lamp settings for this code — only schedule analogue
- Max/min film weight per pass for through-cure, recoatability, sanding/polishing after cure
- Hardness, elasticity, lightfastness/yellowing data
- Shelf life and packaging sizes
- Compatible sealers — not officially stated for this code