Skip to content
UV-curePutty

VTS20014

VTS20014 UV-cure roller filler (catalog: clear universal UV filler-primer)

Mix calculator

g
Thinner1.5 %

When: Only if the material is too heavy for the rollers in a cold shop

Ratio 100 : 1.5

ComponentWeigh out
VTS20014part A493 g
S30 / S31Thinner7.4 g
Total500 g

Covers roughly 15.38 m² at 33 g/m².

Pot life of the mix: n/a — 1K UV-cure, no hardener; stays workable in the trough until exposed to UV.

Ask about VTS20014

Answers are based on the VTS20014 data and the products it mixes with.

Questions and answers are stored to improve the assistant and prevent abuse; the question text is processed by Anthropic (USA). Privacy policy

Mixing matrix

  • Thinner
    % by weight: 0 %recommended% by volume: 0 %recommended

    Standard — use as supplied

    It is 100 % solids: adding solvent hurts the cure and causes pinholes/bubbles.

  • S30 / S31Thinner
    % by weight: 0–3 %recommended% by volume: 0–4 %recommended

    Only if the material is too heavy for the rollers in a cold shop

    Warming the material to 22–25 °C is better than thinning. If thinned, flash off before the lamps.

Percentages are per 100 parts of component A.

Characteristics

Solids
100catalog
Adhesion and wetting
good wetting and adhesion to various substratesofficial
Sanding
easy to sandcatalog
Pore filling
goodcatalog
Pot life
n/a — 1K UV-cure, no hardener; stays workable in the trough until exposed to UVrecommended
Drying · Cure
UV lamp, start at 1 lamp 80–120 W/cm, 10 m/min (gel cure, sandable/overcoatable straight off the line)recommended
Drying · Conditions
UV cure; ambient 18–25 °C typical

Colours

  • clear · clear

Application

Roller coater (UV)

Consumption
30–35 g/m²official
Wet film
25–33 µmrecommended
Coats
1–2 passes (filler roller, often reverse/smoothing roller after)recommended
Flash-off
0recommended
Recoat
immediately after UV gel cure (1 lamp 80–120 W/cm, 10 m/min), then UV primers 20–25 g/m²recommended
Sanding between coats
normally no sanding after the filler; sand after the primer build, P240–P320 (as in the UV schedules)recommended
Nozzle
n/a — roller-only product, not for sprayingrecommended

Filler (doctor/applicator) roller + reverse/smoothing roller on flat parts; cure in-line immediately.

Process and compatibility

Substrate preparation
Sand P150–P180–P220; if staining, CPS stain 60–80 g/m², dry 20–25 °C 5 min (anegri UV schedule) — or VTS20000 sealer 8–10 g/m², dry 30–35 °C 5 min (parquet UV schedule) — before the fillerschedule
Goes over
bare wood/veneer / CPS stain mixes (schedule analogue) / VTS20000 (parquet sealer, schedule analogue)
Sanding
No intermediate sanding needed after filler; sand the cured primer build P240–P320recommended
Temperature and humidity
Material and parts 18–25 °C, RH 50–70 %; wood MC 8–10 %recommended
Don'ts
  • Do not spray — roller only
  • Do not leave the trough in sunlight/UV
  • Do not thin unless you have to
  • Not for profiled parts

Storage

Storage temperature
Store in closed opaque container away from light, 5–30 °Crecommended

Safety: UV acrylates are skin sensitisers: nitrile gloves, eye protection; shield eyes from lamp radiation.

Sources

Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).

Not covered by the sources
  • dealer page: VTS20014 not found by t-colormarket.ru search (re-checked 2026-10-05) nor on lakokraska31/woodonline/ndom31
  • no TDS found (web search budget exhausted)
  • viscosity, density, gloss, hardness, chemical resistance — unpublished
  • UV cure dose/lamp settings specific to VTS20014 (derived from VTS20011 schedule)
  • shelf life and packaging
  • not used in any official finishing schedule
  • lamp unit: schedules print «80–120 Вт» without /cm; W/cm assumed
  • VTS20014 is absent from the 2025-2026 catalog transcripts (only in the older Katalog-Technocolor_web.pdf) — may be discontinued