  • White high-gloss topcoat for furniture fronts and panels on spray lines with UV curing

Mix calculator

g
Thinner20.0 %

S11: 20.0 % — fixed by the datasheet

When: Analogue from the official schedule: UV lacquer VTL30040 : S11 = 100 : 20 sprayed on mouldings. Not published for VPL60100 — a reference point, not a spec.

Ratio 100 : 20.0

ComponentWeigh out
VPL60100part A417 g
S11Thinner83.3 g
Total500 g

Covers roughly 4.35 m² at 115 g/m².

Ask about VPL60100

Answers are based on the VPL60100 data and the products it mixes with.

Questions and answers are stored to improve the assistant and prevent abuse; the question text is processed by Anthropic (USA). Privacy policy

Mixing matrix

  • S13 / S30 / S31Thinner
    % by weight: 0–10 (typ. 5) %recommended% by volume: 0–14 (typ. 7) %recommended

    Only to trim spray viscosity. S31 is the default (medium evaporation); S13/S30 when you need a fast flash-off.

    No hardener — single-component UV system. All solvent must be gone before the lamp, or you get bubbling and dull patches.

  • S11Thinner
    % by weight: 20 %schedule% by volume: 28 %recommended

    Analogue from the official schedule: UV lacquer VTL30040 : S11 = 100 : 20 sprayed on mouldings. Not published for VPL60100 — a reference point, not a spec.

    S11 is catalogued for polyester gloss lacquers; use with the enamel only after a test panel.

Percentages are per 100 parts of component A.

Characteristics

Gloss
высокий глянец (high gloss)official
Drying · Cure mechanism
УФ-отверждение (UV cure) — category 'Материалы УФ отверждения'official
Drying · Pre-dry
30–35 °C, 5–10 мин (5–10 min) before UV lampsschedule
Drying · UV cure
80–120 Вт (W) лампы ×3, 10 м/мин (m/min)schedule
Drying · UV lamp type
Hg + Ga-doped (Fe/Ga) lamp combination; slower belt than for clear lacquersrecommended
Drying · Conditions
line / 20–35 °C

Colours

  • VPL60100 · white

Application

HVLP

Consumption
110–120 g/m²official
Nozzle
1.5–1.8 mmrecommended
Pressure · air
2–2.5 barrecommended
Spray viscosity
18–24 s DIN4 (20 °C)recommended
Wet film
80–100 µmrecommended
Coats
1 full coat over a sanded UV/PU primerrecommended
Flash-off
5–10 min at 30–35 °C before the lampschedule
Sanding between coats
If recoating: cure fully, sand P320–P400, dedust, recoatrecommended

Use opaque hoses and cups (metal or UV-blocking plastic); do not leave material in a translucent cup in daylight — it will start to gel.

Conventional spray

Consumption
110–120 g/m²official
Nozzle
1.5–1.8 mmrecommended
Pressure · air
3–4 barrecommended
Transfer
до 40 %official

Transfer efficiency up to 40 % (official methods page).

Airmix (air-assisted airless)

Consumption
110–120 g/m²official
Nozzle
0.23–0.33 mmrecommended
Tip (thou)
9–13 thourecommended
Pressure · fluid
null–20 barofficial
Pressure · Fluid working pressure
60–100 barrecommended
Pressure · air
1–2 barofficial

For topcoats airmix is preferred over airless (official methods page).

Electrostatic

Possible with all spray types (official methods page). Our note: for a white enamel check the material's resistivity first.

Process and compatibility

Substrate preparation
MDF/panels primed with white UV primer VPS60011 (or compatible PU white primer), cured, sanded P320–P400, dedustedrecommended
Goes over
VPS60011
Sanding
Primer P320–P400 before enamel; between enamel coats P400 after full curerecommended
Temperature and humidity
Material and room 20–25 °C, RH 50–70 %; pre-dry 30–35 °Crecommended
Don'ts
  • Do not add hardeners or PU/acrylic components — it is not a 2K system
  • Do not send to the lamp without a flash-off — solvent will boil
  • Do not lay more than ~120 g/m² per pass (official rate 110–120 g/m²) — white pigment blocks through-cure of a thick film
  • Do not store or hold in clear containers in light

Storage

Safety: Contains reactive acrylate monomers — skin sensitiser: nitrile gloves, goggles, ventilation. UV lamps — shield eyes and skin from the radiation.

Sources

Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).

Not covered by the sources
  • No dealer page: t-colormarket.ru search for VPL60100 returns nothing (UV range not sold there); woodonline.ru no result
  • No TDS found (web search budget exhausted; t-colormarket.ru search re-checked 2026-10-05 — no result)
  • Solids %, viscosity, density, numeric gloss units, lamp dose (mJ/cm²), lamp type
  • Thinner type and ratio (only catalog applicability of S13/S30/S31 to UV materials)
  • Pot life / shelf life / storage temperature / packaging
  • Not used in any official finishing schedule
  • Compatible primer not officially stated (VPS60011 inferred)
  • Hardness, chemical resistance, lightfastness/yellowing data