PolyurethaneEnamel

PPL01

PPL01 white fire-retardant PU enamel, matt (20 gloss)

Two-pack white matt polyurethane enamel with fire-retardant additives. Good hiding power, good physical and chemical resistance. When heated the fire-retardant components break down and give off a non-combustible gas that cuts off oxygen and slows flame spread. Over the PPS01 fire-retardant primer it rates Group I fire-protection efficiency to GOST R 53292-2009 (cl. 6.1). No official t-color.ru page — data from the dealer (t-colormarket.ru) and the Technocolor 'Fire-retardant materials' leaflet.

  • protecting interior timber structures and raising their fire resistance
  • white opaque fire-retardant finish: wall panelling, doors, furniture, public-building interiors
  • top coat of System 2 (pigmented): PPS01 → PPL01, Group I to GOST R 53292-2009

Mix calculator

g
Hardener50.0 %

PC20: 50.0 % — fixed by the datasheet

When: Standard option; slightly more elastic film.

Thinner25.0 %

When: Always; S50 is the universal, normal-evaporation thinner (verticals, normal shop).

Ratio 100 : 50.0 : 25.0

ComponentWeigh out
PPL01part A286 g
PC20Hardener143 g
S50Thinner71.4 g
Total500 g

Covers roughly 3.33 m² at 150 g/m².

Pot life of the mix: 4 h.

Ask about PPL01

Answers are based on the PPL01 data and the products it mixes with.

Questions and answers are stored to improve the assistant and prevent abuse; the question text is processed by Anthropic (USA). Privacy policy

Mixing matrix

  • PC20Hardener
    % by weight: 50 %dealer% by volume: 70 %dealer

    Standard option; slightly more elastic film.

    Dealer and leaflet list PC20 / PC60 as alternatives — use one or the other, don't blend.

  • PC60Hardener
    % by weight: 50 %dealer% by volume: 70 %dealer

    When the white must resist yellowing (bright interiors, near windows, under lighting).

    Same ratio, 50 % by weight / 70 % by volume.

  • S50Thinner
    % by weight: 20–30 (typ. 25) %dealer% by volume: 30–35 %dealer

    Always; S50 is the universal, normal-evaporation thinner (verticals, normal shop).

    20 % for verticals and maximum build; 30 % on flats for better flow-out. Thinner doesn't change cure time.

  • S80Thinner

    Only in hot weather (above ~25 °C) or on large flat panels, instead of S50.

    More dust pick-up and sag risk; avoid on verticals. Fire tests were done with S50 — stick to S50 on certified jobs.

Percentages are per 100 parts of component A.

Characteristics

Solids
64 ± 1 %dealer
Viscosity
10 ± 5 sdealer
Density
≈1.3–1.45 g/cm³ (part A) g/cm³recommended
Gloss
20 ± 3 GU (measuring angle not stated by dealer; 60° assumed)dealer
Pot life
4 hdealer
Drying · Touch-dry
30 mindealer
Drying · Full cure
8 hdealer
Drying · Sand or stack
4–8 h (denib after ~4 h, stack/pack after 8 h + overnight preferred)recommended
Drying · Conditions
20 °C
Drying · Fast drying
fast dryingcatalog
Hardness
scratch resistant; sands easilycatalog
Chemical resistance
хорошая / высокая физико-химическая стойкость / good-to-high physical and chemical resistancedealer
Hiding power
high hiding powerdealer
Flow
excellent flow-outcatalog
Fire protection
Group I fire-protection efficiency, GOST R 53292-2009 cl. 6.1dealer
Lightfastness
good with PC60, moderate with PC20 (white may yellow slightly with time)recommended
Durability
long service lifecatalog

Colours

  • PPL01 · white

Application

HVLP

Consumption
150 g/m²dealer
Pressure · fluid
gravity cup; pressure pot 0.8–1.5 barrecommended
Coats
1 full coat at 150 g/m², or 2 lighter wet-on-wet passes adding up to 150 g/m²recommended
Recoat
after ~4 h with a denib; within 24 h without heavy sandingrecommended
Sanding between coats
P320–P400 or grey pad, denib onlyrecommended

HVLP, 1.8 mm (1.7–1.9), 2.0–2.5 bar inlet trigger pulled, ≤0.7 bar at the cap, fan fully open, 15–20 cm, 50–75 % overlap. Stir part A right to the bottom first (dealer: 'mix thoroughly before use') — the fire-retardant fillers settle. Strain the mix (125–190 µm). Keep the 150 g/m² rate even — both the fire rating and an even matt sheen depend on it. source

Conventional spray

Consumption
150 g/m²dealer

Air spray: transfer efficiency up to ~40 % (methods page) — you'll use more than 150 g/m² of material per part. official

Airmix (air-assisted airless)

Nozzle
09–11 thou (0.23–0.28 mm), 40–50° fanrecommended

For production runs of panels and doors. Not published by Technocolor — test first and check the 150 g/m² rate by weighing a test panel.

Airless

Nozzle
11–13 thou (0.28–0.33 mm)recommended

Large flat parts only; finish quality is below airmix/HVLP.

Brush

Not recommended: Technocolor lists spray only and the fire rating is for spraying at 150 g/m². Brush only for small touch-ups, not on certified work. recommended

Process and compatibility

Substrate preparation
Dry timber/plywood/MDF (8–12 % MC), sanded P180–P240 and de-dusted. Prime with PPS01 fire-retardant primer (150 g/m²), sand P280–P320 when dry, de-dust, then PPL01.recommended
Goes over
PPS01
System
Система 2 (пигментная): PPS01 + (PC20 или PC60 50 %) + S50 20–30 % → PPL01 + (PC20 или PC60 50 %) + S50 20–30 %; распыление, 150 г/м² каждый; I группа ГОСТ Р 53292-2009catalog
Temperature and humidity
18–25 °C, RH 50–70 %; part A and hardener at room temperaturerecommended
Don'ts
  • don't go under or over 50 % hardener
  • don't apply less than 150 g/m² — the fire rating is for this system at this rate
  • don't swap PPS01 for an ordinary primer if you need the GOST fire rating
  • not for exterior use — interior only
  • don't use the mix past 4 h pot life
  • don't sand or polish the final matt coat — you'll get shiny patches
  • don't leave the hardener can open

Storage

Packaging
1 kg,5 kg,25 kgdealer
Shelf life
not published — typically 12 months unopenedrecommended
Storage temperature
+5…+30 °C, sealed, away from heat and flamerecommended

Safety: Solvent-borne 2K PU: flammable (the cured film is fire-retardant, the wet material is not). The hardener contains isocyanates — airway and skin sensitiser. Use an extracted booth, A2P3 respirator or air-fed mask, nitrile gloves and goggles.

Used in finishing systems

    Mixed into

    PC20 / PC60

    Sources

    Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).

    Not covered by the sources
    • no official t-color.ru product page (fire-retardant section empty)
    • no Technocolor TDS/SDS PDF found (web search budget exhausted this session; leaflet + dealer only)
    • density not published (derived)
    • shelf life not published
    • stack/sand time, recoat window not published
    • nozzle/pressure not published (derived)
    • hardness / lightfastness / elasticity numbers not published
    • no finishing schedule on t-color.ru uses PPL01
    • S80 not approved for PPL01 by Technocolor (derived option only)
    • whether a non-fire-retardant topcoat over PPL01 keeps the Group I rating — not stated
    • tint (RAL/NCS) availability stated only range-wide in the leaflet, not for PPL01 specifically
    • PPS01 with PC60: leaflet lists PC20/PC60 for System 2, but the PPS01 dealer page lists PC20 only
    • CF-8 cup not defined by Technocolor (taken as 8 mm flow cup); no DIN4 value for part A or spray mix published
    • dealer S50 weight→volume pair (20–30 wt % → 30–35 vol %) is internally inconsistent at the 30 % end