ATL90 SG
ATL90 SG acrylic lacquer, semi-gloss (40 gloss units)
Fast-drying acrylic lacquer (catalog). Fast drying, non-yellowing over time, brings out the wood pores and has a low tendency to raise the grain. Sands well (dealer).
- Finishing items made of any wood species
- General furniture
- Top coat over an acrylic primer, incl. open-pore finishes
Mix calculator
Ask about ATL90 SG
Answers are based on the ATL90 SG data and the products it mixes with.
Mixing matrix
- % by weight: 10–20 (typ. [object Object]) %official% by volume: 10–20 %official
Always — it's a 2K lacquer. AC40 is the standard; AC41 is the listed alternative (pricier).
Official site and catalog: 10–20 %.
- % by weight: 10–20 %dealer% by volume: 10–20 %dealer
Dealer (t-colormarket) recipe — 10–20 %.
Matches the official range.
- % by weight: 10–20 %catalog
Catalog 2025–2026
- % by weight: 20–30 (typ. [object Object]) %official% by volume: 25–35 %official
S80 / S70 — slow: heat, big flat panels, better flow-out. S50 is not listed on the official page for this gloss grade.
Thinner doesn't change cure time, only evaporation speed (workshop notes).
- % by weight: 20-30 %dealer% by volume: 25-35 %dealer
Dealer recipe
- % by weight: 20–30 %catalog
Catalog 2025–2026 (whole ATL90 line)
- % by weight: 30–40 %schedule
Analogue only: official acrylic schedules run ATL20 lacquer at C40 20 % + S50 40 % / S80 30 % (+CTS 0.5 %). ATL90 isn't named in any schedule — reference only.
| Role | Material | % by weight | % by volume | When |
|---|---|---|---|---|
| Hardener | AC40 / AC41 | 10–20 (typ. [object Object]) %official | 10–20 %official | Always — it's a 2K lacquer. AC40 is the standard; AC41 is the listed alternative (pricier).Official site and catalog: 10–20 %. |
| Hardener | AC40 / AC41 | 10–20 %dealer | 10–20 %dealer | Dealer (t-colormarket) recipe — 10–20 %.Matches the official range. |
| Hardener | AC40 / AC41 | 10–20 %catalog | — | Catalog 2025–2026 |
| Thinner | S80 / S70 | 20–30 (typ. [object Object]) %official | 25–35 %official | S80 / S70 — slow: heat, big flat panels, better flow-out. S50 is not listed on the official page for this gloss grade.Thinner doesn't change cure time, only evaporation speed (workshop notes). |
| Thinner | S80 / S70 | 20-30 %dealer | 25-35 %dealer | Dealer recipe |
| Thinner | S50 / S70 / S80 | 20–30 %catalog | — | Catalog 2025–2026 (whole ATL90 line) |
| Thinner | S50 / S80 | 30–40 %schedule | — | Analogue only: official acrylic schedules run ATL20 lacquer at C40 20 % + S50 40 % / S80 30 % (+CTS 0.5 %). ATL90 isn't named in any schedule — reference only. |
Percentages are per 100 parts of component A.
Characteristics
- Solids
- 29 %catalog
- Viscosity
- 40 ± 3 sdealer
- Gloss
- 30 ± 3 GUdealer
- Pot life
- 6 hdealer
- Drying · Touch-dry
- 20 mindealer
- Drying · Full cure
- 6 hdealer
- Drying · Conditions
- 20 °C
- Drying · Sand or stack
- 1 hdealer
- Drying · Dust-free
- 20 minrecommended
- Drying · Forced drying
- 30–35 °C, 1.5 hrecommended
- Lightfastness
- non-yellowingofficial
- Sandability
- sands wellrecommended
- Grain raising
- low grain raiseofficial
- Thixotropy
- norecommended
Application
HVLP
- Nozzle
- 1.3–1.5 mmrecommended
- Pressure · air
- 2–2.2 barrecommended
- Spray viscosity
- 18–22 s DIN4/VZ-4recommended
- Consumption
- 150 g/m²official
- Wet film
- 140–160 µmrecommended
- Coats
- 1–2 coatsrecommended
- Flash-off
- 10–20 minrecommended
- Recoat
- 1–24 hrecommended
- Sanding between coats
- P320–P400 (denib)recommended
- Gun distance
- 15–20 cmrecommended
HVLP gun, 1.3–1.5 mm tip, 2.0–2.2 bar at the inlet with the trigger pulled, fan wide open, 50–75 % overlap, 15–20 cm off. Spray at ~20 s DIN4.
Conventional spray
- Nozzle
- 1.4–1.6 mmrecommended
- Pressure · air
- 3–3.5 barrecommended
- Spray viscosity
- 18–22 s DIN4/VZ-4recommended
- Consumption
- 150 g/m²official
Air spray is the catalog method (pneumatic spray icon). Transfer efficiency up to ~40 %, so budget more lacquer per piece.
Airmix (air-assisted airless)
- Nozzle
- 0.23–0.28 mmrecommended
- Tip (thou)
- 9–11 thourecommended
- Pressure · fluid
- 60–90 barrecommended
- Pressure · air
- 1–2 barrecommended
- Spray viscosity
- 20–25 s DIN4/VZ-4recommended
- Consumption
- 150 g/m²official
For production runs of panels/doors. Official methods page quotes low hydraulic pressure and 1–2 bar air; real airmix pumps for clears usually sit at 60–90 bar fluid — start low.
Electrostatic
- Why ru
- На официальной странице указано только распыление; на странице методов сказано, что все системы распыления могут быть электростатическими.
Possible on top of any spray system (official methods page) — chairs, legs. Check mix conductivity; slow S70/S80 thinners usually work.
Process and compatibility
- Substrate preparation
- Sand flats P150–P220, profiles K60–K80, de-dust. Over primer: sand P240–P320.recommended
- Sanding
- Between coats P320–P400 after 1 h at 20 °C. Don't sand or polish the final coat on matt/satin grades.recommended
- Temperature and humidity
- 18–25 °C, 50–70 % RH; above 25 °C use S80/S70.recommended
- Don'ts
- Don't use the mix past its 6 h pot life
- Never spray it without hardener
- Don't lay it on heavy in one pass — solvent pop risk
- Don't sand the final matt coat
Storage
- Packaging
- 1 л,5 л,25 лdealer
Safety: Flammable. Contains organic solvents; the hardener is an isocyanate. Spray in a booth, wear an organic-vapour respirator (A2P2/A2P3), gloves and goggles.
Mixed into
Sources
Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” is our engineering estimate (hover to see the reasoning).
- official product page: properties, hardener/thinner %
- dealer page: gloss, viscosity, pot life, drying, solids (if shown), mix table, packs
- application methods (airmix air 1–2 bar, electrostatic)
- analogous acrylic schedules (ATL20/ATS20/C40) — also decape schedule
- analogous acrylic schedule (APS20/APL20/CQS/ATL20 with C40, S50)
Not covered by the sources
- density
- hardness
- chemical_resistance
- elasticity
- shelf_life
- storage_temp
- official TDS/SDS PDF (none found)
- sourced spray nozzle/pressure (all derived)
- grade-specific solids (catalog family value 29 % used)
- gloss conflict: official 40 gl vs dealer 30 ± 3 GU